Trane RTAC Chiller
Air-Cooled Chiller

Trane RTAC
Air Cooled Chiller

 
 

Trane RTAC Chiller - Trane Air Cooled Chiller

For parts or service please contact your local Trane dealer.

 
   
 
    
High Density In-Rack Cooling
In Rack Cooling
Supplemental Cooling
Supplemental Cooling
High Density In-Row Cooling
In Row Cooling

Hot-Aisle/Cold Aisle Layout
Hot-Aisle / Cold Aisle Layout

    
 
 

The Trane Air-Cooled Chiller Model RTAC is the second generation of the air-cooled Series R chiller family. The RTAC offers high reliability, reduced sound levels, improved energy efficiency, and a smaller physical footprint, all due to its advanced design, low speed/directdrive compressor, and proven Series R chiller performance.

The Trane RTAC air-cooled chiller was designed to meet the demanding requirements of today's environment. The high-technology design transforms technology into the performance you can depend on. For example, its semihermetic,  direct-drive compressor eliminates the need for a gearbox, a common component in many competitive chillers. This improves the unit's reliability, energy efficiency, and significantly aids in reducing unit sound levels and vibration.

Also, the Adaptive Control microprocessor aids in improving energy efficiency and provides more reliable operation by minimizing "chiller downtime". This is accomplished with the microprocessor control, which continuously monitors the operating conditions of the chiller and automatically initiates corrective action, especially during adverse conditions.

A look inside the Trane RTAC Chiller

A look inside the Trane RTAC Chiller

The Trane RTAC offers many benefits:

Features:

  • Sizes from 140 to 500 tons.
  • Helirotor compressor is direct drive, low speed (3600 rpm). The only moving parts are the rotors and load/unload mechanisms for high reliability and efficiency.
  • Two independent refrigerant circuits.
  • Tracer Chiller Controller and the Adaptive Control microprocessor provide all unit control and safety functions in a proactive control strategy.
  • Units shipped ready to install with refrigerant (R-134a) and oil, need only electrical and water connections.
  • All units meet ASHRAE 90.1-2001 efficiency guidelines.
  • All units have single inlet & outlet evaporator water connections.
  • Integrated Comfort system capability.
  • Optional remote evaporator (140-250 tons), assembled separately at the factory
  • Optional Standard or High Efficiency units

 

 

 

 
Data Center DesignData Center Cooling
Data Center Power Data Center Management
Data Center Solutions

Home | Contact Us | About 42U | Careers | Clients | Vendors | Glossary | Press | Copyright | Privacy Policy | Site Map

Follow us on:
42u on Twitter 42U on YouTube 42U on slideshare

Copyright© 2012 42U. All Rights Reserved


Trane RTAC Chiller - Trane Air-Cooled Chiller