SynapSoft Data Center Monitoring Software

Free Project Consultation
Free Liebert CRV Consultation
Request Price Quote
Request Quote
PUE Calculator / DCiE Calculator
PUE / DCiE Calculator
SynapSense Wireless Sensors LiveImaging & PowerImaging
SynapSense Wireless Sensors
     
 

Measuring efficiency with SynapSense SynapSoft can help you reduce computer room operation costs in your computer room by improving energy efficiency and implementing power and cooling best practices.

SynapSoft Software from SynapSense

SynapSoft provides real-time, complete data center monitoring and visibility, allowing data center managers and facilities operators to make changes to their floor plan and energy use, while reducing their risk of downtime and reducing energy costs. This ground-breaking, green energy solution is comprised of a complete wireless hardware and software solution set designed specifically for large and global data centers (5K-10K sq. ft. minimum).

SynapSense SnapSoft
SynapSoft 4.0 - Thermal Map

SynapSoft 4.0 also features LiveImaging, the first real-time energy and operational efficiency solution that enables data center operators to literally see temperature, humidity, and pressure trends in their data center, and take corrective action with confidence. LiveImaging maps highlight your specific environmental conditions using 3D real-time data at multiple levels of the data center, and provide a visual display of actual examples of thermal air mixing, pressure differential, and humidity.

 

SynapSoft 4.0 - Pressure Map
SynapSoft 4.0 - Pressure Map

SynapSoft 4.0 - Humidity Map
SynapSoft 4.0 - Humidity Map

LiveImaging

The LiveImaging feature in SynapSense's SynapSoft software provides thermal, pressure differential, and humidity mapping using 3D real-time data at multiple levels of your data center enabling you to literally see hot spots and direct airflow to avoid over-heating or air mixing. LiveImaging pressure mapping enabled one customer to dramatically increase sub-plenum pressure differential by 60%, thereby improving airflow to such an extent, they were able to turn off a CRAC unit.

SynapSoft LiveImaging benefits include:

  • An integrated view of the data center environment, and a record of anomalies

  • Real-time visibility of the impact of data center changes

  • Identifies energy efficiency improvement opportunities

  • Identifies available cooling for increased CPU density and footprint reclaim

  • Addresses potential energy savings, operational savings, and data center resiliency

  • Supports cooling capacity management by depicting real-time impact of changes

LiveImaging provides global real-time views of your data center

SynapSoft includes more than a dozen configurable views that help you ‘see'your data center; everything from a high-level overview, to customized zone views, down to detailed views of the temperature efficiency of a single rack, historical performance of CRACs, and much more.

  • Data Center View: Gives an overview of the entire data center with zone icons, which are colored red, green or yellow to depict alert status within each of the zones - includes Zone View drill-down options.
  • Zone View: Gives at-a-glance, vital, environmental statistics including temperature, humidity and pressure. It can also isolate a desired physical parameter and acts as a landing page from which a user can drill down to view detailed temperature and humidity historical data of CRACs and racks.
  • Zone Node View: Allows sorting by data type. This provides a snapshot of data such as high and low temperatures or extreme humidity.
  • CRAC View: Provides a seven-day historical graph of CRAC relative humidity, supply and return temperatures and CRAC efficiency.
  • Rack View: Provides temperatures for both the hot and cold aisle sides of the rack, relative humidity and quantifies the CSI (cold supply infiltration), which is a measure of cold air loss through mixing.
  • Row Environmentals: Any number of sensors can be graphed through the "Data Analysis" functionality. SynapSoft 4.0 enables a group of sensors to be named and saved for future reporting with a single click. This allows you to quickly create a preferred view with your most recent data or use historical data to view past trends.

 

About 42U
42U focuses on providing Facilities and Data Center Managers with objective and trusted independent information on Data Center Power and Data Center Cooling best practices along with KVM over IP and Remote Power lights out management to help them reduce their organization's power consumption.  Our Data Center Management website has helped millions of IT professionals globally who search for best practices and technologies to help them make their computer environment more efficient.

Creative Commons License
This work is licensed under a Creative Commons Attribution-No Derivative Works 3.0 Unported License.

 


 Home About 42U Careers Clients Vendors Press Articles Efficiency Glossary Site Map Efficiency Calculator
Data Center Solutions UPS Power Data Center Efficiency Efficiency Services Rack Accessories Efficiency Best Practices Lights Out
Follow us on:
 Follow 42u on Twitter Subscribe to 42U's channel on YouTube View 42u's profile on slideshare


SynapSoft LiveImaging from SynapSense