SynapSense Active Control Automated Data Center Cooling Control Software

By automatically adjusting cooling capacity to meet changes in IT load, SynapSense Active Control™ provides increased efficiency and immediate energy savings. SynapSense Active Control dynamically manages CRAH temperature set points and fan speeds by monitoring server inlet temperature and subfloor pressure differentials via SynapSense's innovative wireless monitoring sensors. This unique approach to cooling control optimizes CRAH capacity and saves 20-35% of cooling costs.

Data Center Assessment and Optimization Services compliment the Active Control Solution by baselining the data center cooling capacity and optimizing airflow prior to implementing Active Control. This serves to increase reliability, availability and capacity. With SynapSense Active Control, data center operators can fully automate cooling of their server rooms, resulting in immediate energy savings and increased efficiency. Active Control allows data center operators to add IT load, while avoiding the capital cost associated with incremental cooling capacity.

The Active Control three-step process includes:

1. Baseline the Data Center, including environmental conditions, total IT load, cooling capacity and cooling efficiency.

Baseline Temperature & Pressure
Baseline Temperature & Pressure

2. Optimize Airflow Management. Using industry best practices, a data driven optimization analysis and set of recommendations is provided, detailing potential optimization opportunities, with corresponding cost, expected energy savings and overall return on investment (including payback period). Optimization includes, rebalancing the raised floor, air-mixing mitigation, and matching cooling capacity to IT load.

Improve Airflow Management
Improve Airflow Management

3. Active Control optimizes cooling capacity and saves 20-35% of cooling costs by minimizing the fan energy to meet server CFM requirements, while maintaining acceptable server inlet temperatures in the ASHRAE range.

SynapSense Active Control Screen Shot

SynapSense Active Control Benefits
  • ROI - Save 20-35% of cooling energy

  • Reliability - Fine grain sensing of both temperature and pressure guarantees control accuracy

  • Responsive - Dynamically controls CRAH set points and fan speeds

  • Scalability - Designed to operate in 5K to >100K sq ft; Leverages scale afforded by SynapSense Environment Environmental Monitoring and Energy Management Solution

  • Ease of Use - Enables user-initiated or system-initiated transitions from Automatic to Manual Mode

 

 

Is SynapSense Active Control the best cooling control system for your data center?
Data Center Consultation
Our engineers can also help you select the best solution.
Click here or Call 1-800-638-2638 for a free project evaluation.

 

 
Data Center EngineeringData Center Cooling
Data Center Power Data Center Management
Data Center Solutions

Home | Contact Us | About 42U | Careers | Clients | Vendors | Glossary | Press | Copyright | Privacy Policy | Site Map

Follow us on:
42u on Twitter 42U on YouTube 42U on slideshare

Copyright© 2012 42U. All Rights Reserved


SynapSense Active Control Data Center Cooling Monitoring Solution