High Density In-Row Cooling

High Density In-Row
Cooling Solutions

 
 

High Density In-Row Cooling Solutions for Server Racks, Computer Rooms, Server Rooms & Data Centers

 
Featured Solution! Featured Solution!
Data Center Curtains AirBlock - Data Center Curtains
Data Center Curtains help you maximize airflow dynamics and increase the effectiveness of your hot aisle /cold aisle isolation. Save energy on air conditioning by as much as 15% to 67% on fans.
 
Liebert CRV In Row Cooling System Liebert CRV - In-Row Precision Cooling
Self-contained precision cooling system that installs within a row of racks-close to the server heat source-for the most efficient cooling of critical IT equipment. Control System modulates performance in real-time.
 
    
APC RC High Density Cooling System
APC RC
APC RP High Density Cooling System
APC RP
Liebert XDO In-Row Cooling System
Liebert XDO
Liebert CRV In Row Cooling System
Liebert CRV
    
Rittal LCP Inline
Rittal LCP Inline
Liebert XDH High Density Cooling System
Liebert XDH

Liebert XDV


High Density Cooling Solutions / High Density In-Row Cooling

What is In-Row Cooling?


Conventional data center cooling floods an entire room with cold air-an approach that works well at minimal power densities. In-Row cooling offers capacity and efficiency gains by moving the air conditioner from the perimeter of the room closer to actual load. Installed on the floor or suspended from overhead, in-row cooling units provide local, focused cooling at the rows of server cabinets which fill the data center.

In-Row: Floormount

The floormount, In-Row air conditioner couples the functionality of a perimeter CRAC unit with a significantly smaller footprint. These products are embedded in rows of data center cabinets, supporting a conventional hot aisle/cold aisle layout.

In-Row: Overhead

Overhead units have a unique value proposition. Suspended from the ceiling or housed on top of a cabinet, these units conserve valuable floor space, leaving more room for servers, storage, and switches.

Overhead systems allow cooling-strapped data centers to add capacities without new construction. For Greenfield data centers, these systems can serve as dedicated cooling or can complement the baseline cooling and humidity control of traditional CRAC units.

High Density, High Efficiency

Distance is the cornerstone of In-Row performance. Neither cool air nor warm exhaust air has far to travel, allowing the units to dissipate high heat loads.


Cooling Medium

In-Row solutions, whether floormount or overhead, consist of fans and a cooling coil. Depending on the product, the cooling coil will utilize chilled water or refrigerant as the cooling medium.

Refrigerant based units will require connection to a remote condenser system while chilled water based units traditionally connect to chiller systems.

The 42U Advantage

42U has sold best-of-breed, high density cooling solutions since their emergence in the marketplace. We understand all of the design nuances and infrastructure considerations: something truly unique to our industry.



Contact us to find the best High Density In-Row Solution for your cooling needs.
Data Center Consultation
Our engineers can help you select the best High Density In-Row Cooling solution for your cooling needs.
Click here or Call 1-800-638-2638 for a free High Density Cooling project consultation.
 


 