APC EcoBreeze
Modular Evaporative Cooling Solution

APC EcoBreeze
Modular Economizer System

    
Free Project Consultation
Free Cooling Consultation
PUE Calculator / DCiE Calculator
PUE / DCiE Calculator

Data Center Energy Efficiency Savings Calculator
Efficiency Savings Calculator
 

APC EcoBreeze Modular Indirect Evaporative Cooling Solution

The APC EcoBreeze is a new data center cooling offering from APC.  This modular cooling solution is ideal for ground level data centers.

*Available Summer 2011!

APC EcoBreeze installed where Aisle Containment is used
EcoBreeze installed where hot air from servers is controlled through Hot Aisle Containment

How it works:

  • The hot air rises to the ceiling plenum and is fed into the return ducting of the EcoBreeze
  • The IT air is then cooled and supplied back to the data center through a raised floor plenum or cold aisle diffusers
  • The cool air is forced through the perforated tiles in front of the server racks and is used to keep the servers at a safe operating temperature
     

APC EcoBreeze installed were ducting is used
EcoBreeze installed where hot air from servers is controlled through ducting connected to the racks

How it works:

  • The hot air rises to the ceiling plenum through ducting and is fed into the hot air return of the EcoBreeze
  • The IT air is then cooled and supplied back to the data center through cold aisle diffusers. The diffusers have a bowling alley type discharge that sends the air down the cold aisle

 

APC EcoBreeze Air to Air heat exchange mode
Cooling Module – Air to Air Heat Exchange

How it works:

  • When ambient air drops below 45°F (setpoint adjustable)

    • System water is dumped to prevent freezing and/or dumped after 24 hours (user adjustable) of spray free operation
  • Only requires power of fans to move the air in this mode
  • Cool air passes over the outside of the heat exchanger channels, cooling the hot IT air flowing inside.

APC EcoBreeze Installation
Rendering of how an installation of the APC EcoBreeze might look.

 

Air-side free cooling availability map

EcoBreeze Features Snap Shot:

  • Two forms of Economization
    • Air-to-Air Heat Exchange
    • Indirect Evaporative Cooling
  • Proportional DX refrigeration circuit
    • Variable Speed Compressor
  • Electronically Commutated Fans
  • Zero White Space Solution
  • Modular Design for “Pay as you Grow” Philosophy
  • Chemical-Free Water Treatment
  • 50kW Sensible Cooling Per Module (No Dehumid/Humid)
  • IEC Heat Exchanger
    • No mixing of IT air and outside air

Electrical Information:

  • Variety of Voltages
    • 208-230/3/60
    • 460-480/3/60
    • 575-600/3/60
    • 400/3/50
  • Amp Draw less than 25A (per module based on 460V)
  • Schneider Electric Controller
  • Redundant Frame Electronics: RIM & MIM
  • ModBUS RTU Interface
  • Single Point Power Connection

     

Watch 42U's "Free Cooling" Webinar:
Free Cooling & Economization 101

 

Is the APC EcoBreeze the best evaporative cooling solution for your cooling needs?
Data Center Consultation
Our engineers can help you select the best cooling solution for your data center.
Click here or Call 1-800-638-2638 for a free cooling project consultation.

 

 