ServerTech POPs - Server Technology Per Outlet Power Sensing Rack PDU
ServerTech's Sentry Switch Per Outlet Power Sensing (POPs) Rack PDU combines all the features and functions of a Switched Cabinet PDU with the ability to provide power monitoring per an individual outlet/device.
Blade servers and high density computing power requirements continue to increase within the Data Center, creating heat proliferation and more challenges for managing the IT environment. To maintain their competitive advantage, data center managers need solutions such as Sentry Switch Per Outlet Power Sensing units that monitor, track and manage servers and IT equipment and the equipment cabinet infrastructure that houses them.

Server Tech POPs Web Interface Screenshot
Server Tech POPS Power information per individual outlet includes: current load (A), voltage (V), power (kW), apparent power (VA), crest factor, and power factor. Using our grouping technology, power information is available per device, groups of devices (application), individual Cabinet PDU or cabinet.
Server Tech Switched POPS units include:
- POPS Switched CDU CWG-16V(C13/C19)
- POPS Switched CDU CWG-24VD/VY(C13/C19)-3Ph
- POPS Switched CDU CWG-24V4(C13/C19)-3Ph.

ServerTech Per Outlet Power PDU Application Diagram
Power Information & Management
The Sentry POPS CDU is capable of being monitored and managed through the SPM (Sentry Power Manager) tool. Sentry POPS, in conjunction with SPM, provides additional power information including kW and kW-h information for billing purposes and power monitoring as well as trending and power reports. An ODBC compliant database allows power and other information to be exported to a Building Management System.
The ServerTech POPs offer many benefits:
Key Features:
![]()
ServerTech Sentry PDU
Outlet Level Power Management
- Simple, secure, integral web interface GUI configuration tool
- Temperature and Humidity Support
- Authentication logging, configuration changes and system events
- Secure Syslog protocol support
- Email notifications of log, event, authorization, power and configuration messages
- Automatic Firmware Updates via FTP server
- Strong Password Support and Pre-Login Banner
- Ability to Ping an IP address to see if the device is responding
- Grouping of outlets across multiple CDU's
- SNMP: Traps based on Status, Changes, Load, Temperature and Humidity
- Supports 104 user accounts and 18 simultaneous logins with a dedicated SNMP connection
Communication Tools
- SSL
- SSH
- SSLv3/TLSv1
- SNMPv2
- TACACS+
- LDAP
- LDAPS
- RADIUS
- DHCP
- Syslog
Outlet Control Power Monitoring
- Individual Outlet Control
- Current Load Monitoring
- Power Monitoring
- Additional Details
Per CDU Power Information
- Current Load
- Infeed Voltage (VAC)
- Input Feed Watts (W)
- System Total Watts (W)
- System Footprint (SqFt or SqM)
- System Watts (W per SqFt and/or Meter)
Grouped Outlets Power Information
- Device (Multiple Outlets)
- Group of Devices (Application)
- Cabinet (single IP address using masterexpansion
configuration for two CDUs) - Individual CDU
Sentry POPS (Per Outlet Power Sensing)
- Current Load (A)
- Voltage (V)
- Power (W)
- Apparent Power (VA)
- Crest Factor
- Power Factor
Selected ServerTech Outlet Sensing PDUs - Call 1-800-638-2638 For more options
| Intelligent Rack PDU (Input Plug Type) | Amps | Nominal Power | Outputs | Form Factor | PDU Image | View Online Pricing Online pricing is provided by |
| 208 Volt Input - 20 Amp (Derated to 16A) | ||||||
| CWG-16V2A313A1 (C20) | 20A | 3.3kW | (12) C13, (4) C19 | 0U | ![]() | Call 800-638-2638 for Best Pricing |
| 208 Volt Input - 30 Amp (Derated to 24A) | ||||||
| CWG-16V2C313A1 (L6-30P) | 30A | 5kW | (12) C13, (4) C19 | 0U | ![]() | Call 800-638-2638 for Best Pricing |
| 208V 3-Phase Delta Input - 20 Amp (Derated to 16A) | ||||||
| Server Tech CWG-24VDD311A1 (L15-20P) | 20A | 5.8kW | (18) C13, (6) C19 | 0U | ![]() | Call 800-638-2638 for Best Pricing |
| 208V 3-Phase Delta Input - 30 Amp (Derated to 24A) | ||||||
| Server Tech CWG-24VDE311A1 (L15-30P) | 30A | 8.6kW | (18) C13, (6) C19 | 0U | ![]() | Call 800-638-2638 for Best Pricing |
| 208V 3-Phase Wye Input - 20 Amp (Derated to 16A) | ||||||
| CWG-24VYL311A1 (L21-20P) | 20A | 5.8kW | (18) C13, (6) C19 | 0U | ![]() | Call 800-638-2638 for Best Pricing |
| 208V 3-Phase Wye Input - 30 Amp (Derated to 24A) | ||||||
| CWG-24VYM311A1 (L21-30P) | 30A | 8.6kW | (18) C13, (6) C19 | 0U | ![]() | Call 800-638-2638 for Best Pricing |
The 42U Advantage
Power is a critical resource and an expensive reality. Let 42U show you how to optimize your power backup, distribution, and measurement for a more efficient server room. With over 17 years of data center infrastructure experience, 42U is a leader in providing outlet monitoring power distribution and a trusted source for manufacturer independent advice. Contact your 42U rack PDU specialist today for a power project consultation at 1-800-638-2638.
More Top Intelligent Rack PDU Solutions
Contact us to find the best intelligent Rack PDU for your power needs.![]()
Our engineers can help you select the best outlet monitoring PDU for your server rack.
Click here or Call 1-800-638-2638 for a free data center project consultation.