ServerTech Monitored Rack PDU

42U's engineers can help you find the right Server Technologies Monitored Rack PDU solution for your current & future power management needs.

ServerTech Smart PDU - Server Technology Monitored Power Distribution Unit

 

ServerTech CDU Capabilities:

  • Branch Circuit Protection
  • Input Current Monitoring
  • Environmental Monitoring
  • Expansion Module
  • Button Mounting

The Smart Cabinet Distribution Unit (CDU) provides reliable power distribution combined with local and remote power monitoring and environmental monitoring via IP.  Use the network interface to view power, temperature and humidity levels via Web browser, or receive SNMP-based alarms and email alerts when conditions exceed defined thresholds.

The Smart CDU family has the capability to daisy chain units together which gives the ability to use one IP address across different power circuits.

Server Technology Smart PDU Web Interface Screen Shot
ServerTech Smart PDU Web Interface Screen Shot

ServerTech Smart PDU Features:

Server Technology Smart PDU
ServerTech Smart PDU
Monitored Rack PDU

  • Flexible Mounting Options- Zero-U button or bracket mounting for mounting vertical CDU's in the back or on the side of the cabinet to avoid consuming valuable "U" space.
  • Branch Circuit Protection- All Sentry CDU's meet the UL 60950-1 requirement for branch circuit protection and use either fuses or circuit breakers to protect each branch of outlets.
  • Input Current Monitoring- The CDU's exclusive True RMS Current Monitoring is critical to preventing overloads in high-density computing environments. Digital LED displays on the CDU enclosure report the input current of each phase or branch circuit.
  • Environmental Monitoring- External probes, with 3-meter cable, capable of measuring temperature & humidity. Receive SNMP-based or email alert notifications when conditions exceed defined thresholds.
  • Expansion Module- Exclusive method for linking additional outlets, on separate CDU's, together under a single IP address, with support for A & B power in-feeds.
  • IP Access, Security & Communications- Web interface, SSL, SSH, Telnet, SNMP and RS- 232 access, 10/100 Base T-Ethernet, SSLv3/TLSv1, SNMPv2, TACACS+, LDAP, LDAPS, RADIUS, DHCP, SMTP/Email, and Syslog.
ServerTech Monitored PDU
(Input Plug Type)
AmpsNominal PowerOutputsForm FactorPDU Image
Monitored Rack PDU - 120 Volt Input - 20 Amp (Derated to 16A)
CS-16V1-C20M
(C20  to 5-15P,5-20P or L5-20P)
20A1.92kW(16) 5-20R0UServer Tech CS-16V1-C20M<br>(C20) Monitored Rack    PDU
CS-24V1-C20M
(C20 to 5-15P,5-20P or L5-20P)
20A1.92kW(24) 5-20R0UServer Tech CS-24V1-C20M<br>(C20) Monitored Rack    PDU
CS-48VD1-C20
(2 x C20  to 5-15P,
5-20P or L5-20P)
20A3.8kW(48) 5-20R0UServer Tech CS-48VD1-C20<br>(C20) Monitored Rack    PDU
Monitored Rack PDU - 120 Volt Input - 30 Amp (Derated to 24A)
CS-24V1-L30M
(L5-30P)
30A2.88W(24) 5-20R0UServer Tech CS-24V1-L30M<br>(L5-30P) Monitored Rack    PDU
CS-48VD1-L530
(2 x L5-30P)
30A5.76kW(48) 5-20R0UServer Tech CS-48VD1-L530<br>(L5-30P) Monitored Rack    PDU
Monitored Rack PDU - 208 Volt Input - 20 Amp (Derated to 16A)
CS-12HD2-L20
(2 x L6-20P)
20A6.7kW(12) C192UServer Tech CS-12HD2-L20<br>(L6-20P) Monitored Rack    PDU
CS-16V2-C20M
(L6-20P)
20A3.33kW(16) C130UServer Tech CS-16V2-C20M<br>(C20) Monitored Rack    PDU
CS-24V2-C20M
(L6-20P)
20A3.33kW(24) C130UServer Tech CS-24V2-C20M<br>(C20) Monitored Rack    PDU
CS-24V2-L20MA
(L6-20P)
20A3.33kW(18) C13,
(6) C19
0UServer Tech CS-24V2-L20MA<br>(L6-20P) Monitored Rack    PDU
CS-48VD2-C20
(2 x L6-20P)
20A6.7kW(48) C130UServer Tech CS-48VD2-C20<br>(C20) Monitored Rack    PDU
CS-84VD2-L620
(2 x L6-20P)
20A6.7kW(84) C130UServer Tech CS-84VD2-L620<br>(L6-20P) Monitored Rack    PDU
Monitored Rack PDU - 208 Volt Input - 30 Amp (Derated to 24A)
CS-12HD2-L630
(2 x L6-30P)
30A10.0kW(12) C192UServer Tech CS-12HD2-L630<br>(L6-30P) Monitored Rack    PDU
CS-16V2-L30M
(L6-30P)
30A4.99kW(16) C130UServer Tech CS-16V2-L30M<br>(L6-30P) Monitored Rack    PDU
CS-24V2-L30M
(L6-30P)
30A4.99kW(24) C130UServer Tech CS-24V2-L30M<br>(L6-30P) Monitored Rack    PDU
CS-24V2-L30MA
(L6-30P)
30A4.99kW(18) C13,
(6) C19
0UServer Tech CS-24V2-L30MA<br>(L6-30P) Monitored Rack    PDU
CS-48VD2-L630
(2 x L6-30P)
30A10.0kW(48) C130UServer Tech CS-48VD2-L630<br>(L6-30P) Monitored Rack    PDU
CS-84VD2-L630
(2 x L6-30P)
30A10.0kW(84) C130UServer Tech CS-84VD2-L630<br>(L6-30P) Monitored Rack    PDU
Monitored Rack PDU - 208V 3-Phase Delta Input - 20 Amp (Derated to 16A)
Server Tech
CS-12HDD-L1520
(2 x L15-20P)
20A, 3ø 11.5kW(12) C192UServer Tech CS-12HDD-L1520<br>(L15-20P) Monitored Rack    PDU
CS-21VD-L1520
(L15-20P)
20A, 3ø 5.8kW(21) C130UServer Tech CS-21VD-L1520<br>(L15-20P) Monitored Rack    PDU
CS-48VDD-L1520
(2 x L15-20P)
20A, 3ø 11.5kW(48) C130UServer Tech CS-48VDD-L1520<br>(L15-20P) Monitored Rack    PDU
CS-84VDD-L1520
(2 x L15-20P)
20A, 3ø 11.5kW(84) C130UServer Tech CS-84VDD-L1520<br>(L15-20P) Monitored Rack    PDU
Monitored Rack PDU - 208V 3-Phase Delta Input - 30 Amp (Derated to 24A)
CS-12HDD-L1530
(2 x L15-30P)
30A, 3ø 17.3kW(12) C192UServer Tech CS-12HDD-L1530<br>(L15-30P) Monitored Rack    PDU
CS-24VD-L30M
(L15-30P)
30A, 3ø 8.6kW(24) C130UServer Tech CS-24VD-L30M<br>(L15-30P) Monitored Rack    PDU
CS-36VDE411
(L15-30P)
30A, 3ø 8.6kW(36) C130UServer Tech CS-36VDE411<br>(L15-30P) Monitored Rack    PDU
CS-48VDD-L1530
(2 x L15-30P)
30A, 3ø 17.3kW(48) C130UServer Tech CS-48VDD-L1530<br>(L15-30P) Monitored Rack    PDU
CS-84VDD-L1530
(2 x L15-30P)
30A, 3ø 17.3kW(84) C130UServer Tech CS-84VDD-L1530<br>(L15-30P) Monitored Rack    PDU
Monitored Rack PDU - 208V 3-Phase Wye Input - 20 Amp (Derated to 16A)
CS-12HDY-L2120
(2 x L21-20P)
20A, 3ø 11.5kW(12) C192UServer Tech CS-12HDY-L2120<br>(L21-20P) Monitored Rack    PDU
CS-21VY-L2120
(L21-20P)
20A, 3ø 5.76kW(21) C130UServer Tech CS-21VY-L2120<br>(L21-20P) Monitored Rack    PDU
CS-48VDY-L2120
(2 x L21-20P)
20A, 3ø 11.5kW(48) C130UServer Tech CS-48VDY-L2120<br>(L21-20P) Monitored Rack    PDU
CS-54VDY-L2120
(2 x L21-20P)
20A, 3ø 11.5kW(12) 5-20R,
(42) C13
0UServer Tech CS-54VDY-L2120<br>(L21-20P) Monitored Rack    PDU
CS-84VDY-L2120
(2 x L21-20P)
20A, 3ø 11.5kW(84) C130UServer Tech CS-84VDY-L2120<br>(L21-20P) Monitored Rack    PDU
Monitored Rack PDU - 208V 3-Phase Wye Input - 30 Amp (Derated to 24A)
CS-12HDY-L2130
(2 x L21-30P)
30A, 3ø 17.28kW(12) C192UServer Tech CS-12HDY-L2130<br>(L21-30P) Monitored Rack    PDU
CS-24VY-L30M
(L21-30P)
30A, 3ø 8.64kW(24) C130UServer Tech CS-24VY-L30M<br>(L21-30P) Monitored Rack    PDU
CS-24VY-L30MA
(L21-30P)
30A, 3ø 8.64kW(18) C13,
(6) C19
0UServer Tech CS-24VY-L30MA<br>(L21-30P) Monitored Rack    PDU
CS-36VYM411
(L21-30P)
30A, 3ø 8.64kW(36) C130UServer Tech CS-36VYM411<br>(L21-30P) Monitored Rack    PDU
CS-48VDY-L2130
(2 x L21-30P)
30A, 3ø 17.28kW(48) C130UServer Tech CS-48VDY-L2130<br>(L21-30P) Monitored Rack    PDU
CS-54VDY-L2130
(2 x L21-30P)
30A, 3ø 17.28kW(12) 5-20R,
(42) C13
0UServer Tech CS-54VDY-L2130<br>(L21-30P) Monitored Rack    PDU
CS-84VDY-L2130
(2 x L21-30P)
30A, 3ø 17.28kW(84) C130UServer Tech CS-84VDY-L2130<br>(L21-30P) Monitored Rack    PDU
Monitored Rack PDU - 208V 3-Phase Wye Input - 60 Amp (Derated to 48A)
CS-12VY-P603
(IEC60309)
60A, 3ø 17.29kW(12) C190UServer Tech CS-12VY-P603<br>(IEC309) Monitored Rack    PDU

(back to top)

The 42U Advantage

Throughout our 16 year history, 42U has made computer environments more productive and efficient through the integration of remote management solutions. Remote power and remote access solutions have been cornerstones of our success. Contact your 42U sales engineer today for a power project consultation at 1-800-638-2638.

Other Top Monitored Rack PDU Solutions

What is the best ServerTech Monitored Rack PDU Solution for your power needs?
 Data Center Consultation
Our engineers can help you select the best Monitored Rackmount PDU for your server rack.
Click here or Call 1-800-638-2638 for a free Data Center project consultation.