ServerTech EMCU-1 Environmental Monitoring Appliance
The Power Tower EMCU-1 assures network managers that environmental
conditions are within defined tolerances and that unwarranted
entry into your equipment cabinets does not go unnoticed.
The EMCU-1 integrates easily with the Power Tower XL. Locate
the EMCU-1 in an equipment cabinet with a PTXL, link it to the
PTXL and view temperature, humidity, water sensing and dry contact
closures from the same PTXL interface you use to manage & monitor
the power.

Ever increasing densities of vertically racked
servers conserve valuable floor space in the data center, but
the resulting power consumption and heat dissipation create
new concerns for data center managers. Environmental Monitoring,
particularly temperature & humidity, is a must for any sensitive
infrastructure.
As server failure rates increase 2-3 percent for every one degree
rise in temperature, monitoring the temperature in equipment
cabinets is vital to the servers’ performance. Introducing the
Power Tower Environmental Monitoring Control Unit (EMCU-1) to
monitor vital environmental conditions in your equipment cabinet.
Prevent environmental conditions from exceeding recommended
thresholds and protect your equipment cabinet’s assets from
harmful elements.
The Power Tower EMCU-1 assures network managers that environmental
conditions are within defined tolerances and that unwarranted
entry into your equipment cabinets does not go unnoticed.
The EMCU-1 can be located in Data centers, co-lo
site, web hosting facilities, telecom switching sites, POP sites,
server closets, and any unmanned area that needs to be monitored.
Link a EMCU-1 to an existing Sentry Power Tower XL in your equipment
cabinet and gain access environmental conditions from the same
interface.
Each EMCU-1 supports two temperature humidity probes, a water
sensor and other dry contact closures. When a dry contact experiences
a change in state or to its defined threshold, it reports an
“error” condition.
ServerTech EMCU-1 Cabinet Environment Status
ServerTech EMCU-1 Cabinet Intrusion Detection
ServerTech EMCU-1 Analog Input Sensor
ServerTech EMCU-1 Notification Warnings
ServerTech EMCU-1 IP Management
-
HTML Web Interface
-
Command Line Interface
ServerTech EMCU-1 Seamless Integration with
the Power Tower XL
-
Simple & fast installation
-
No external Power source required
-
Dedicated IP address not required
-
No additional software required
-
Flexible Zero U mounting
|
Environmental Monitoring |
|
EMCU |
|
Item # |
Description |
|
EMCU-1-1 |
Environmental Monitor
control Unit w/ 1 Temp & Humidity Probe (10') |
|
EMTH-1-1 |
Temp & Humidity Probe
(10') |
|
EMWS-1-1 |
Water Sensor Probe (15') |
| |
|
|
Measurement Range |
0-100% RH |
|
Absolute RH accuracy |
+/- 3.5% RH |
|
Repeatability RH |
+/- 0.15 RH |
|
Temperature accuracy |
+/- 0.5°C |
|
Open Position |
Power source for peripheral
analog sensor (+5 vdc, Signal, GND) |
|
Water Rope |
Thermally bonded polymer
coated carrier |
|
Wago Spring-loaded terminal
blocks |
Support up to 4 normally
open or normally closed dry contact closures |
|
LED Confirmation Indicators |
Signal “Fault” conditions
to contact closures |
|
Communications link to
PTXL & PTXM |
6-wire rolled RJ-12 cable,
5’ |
|
Dimensions |
4.5” x 2.25” x 1” |
|
Weight |
8.8 oz |
|
Mounting |
Mounting tabs included
for zero U mounting |
|
Warranty |
1 year |