ServerTech CDU-10h Metered Power Distribution

ServerTech CDU-10h
ServerTech CDU-10h

ServerTech CDU-10h Metered Power Distribution
Power distribution with LED input current display and branch circuit protection.

Server Technology's CDU-10h Sentry CDU product family uniquely meets these demands. Server Technology's CDU-10h Sentry Cabinet Power Distribution Unit (CDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the CDU's True RMS Power Monitor to precisely measure the current (in amps) that network devices aredrawing on the power circuit. As new servers and devices are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.

ServerTech CDU-10h Features:

  • Branch Circuit Protection: The Sentry CDU Family meets the new UL 60950-1 requirement for branch circuit protection. Attention! The Sentry CDU products meet the above criteria by providing overcurrent protection with UL-listed Bussman SC fuses for each branch circuit.
  • Branch Current Monitoring: The CDU's exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase or branch circuit.
  • Button Mounting:  All CDUs are also compatible with new button & "keyhole" style mounting for cabinets. Several cabinet manufacturers are now using this method for installing power distribution units in the cabinet.
  • Cabinet Power Distribution: Reliable single & three-phase power distribution for all the devices in your equipment cabinet. Choose a single or dual-power feed model to run all power cables to one side of the cabinet -- leaving the other side open for data cable management

ServerTech CDU-10h Metered Power Distribution  Specifications:

 

Item #

Available Input Voltages

Rated Amperage

Available Input Cord

Outlets

Dimensions

C-10H
C-10H1-C20 100-120V 50/60Hz 20/30A IEC 60320/C20 Power Inlet (10) NEMA 5-20R 1.75" (H)
17.0"W, 10"D
C-10H1-L530 100-120V 50/60Hz 20/30A NEMA L5-30P Cordset (10) NEMA 5-20R 1.75" (H)
17.0"W, 10"D
C-12H2-C20 208-240V 60Hz 20/30A IEC 60320/C20 Power Inlet (12) IEC 60320/C13 1.75" (H)
17.0"W, 10"D
C-12H2-L630 208-240V 60Hz 20/30A NEMA L6-30P Cordset (12) IEC 60320/C13 1.75" (H)
17.0"W, 10"D
 
 
Server Tech Power Cord Options Part Number
IEC 60320/C19 to L6-20P, 10'(PTCORD-1) PTCORD-1
IEC 60320/C19 to Schuko, 10'(PTCORD-2) PTCORD-2
IEC 60320/C19 to IEC 60309 (BS4343, CEE17) 16/20A Blue (PTCORD-3) PTCORD-3
IEC 60320/C19 to BS1363 13A (UK), 10'(PTCORD-4) PTCORD-4
IEC60320/C19 to 5-15P , 10'(PTCORD-5) PTCORD-5
IEC60320/C19 to 5-20P, 10'(PTCORD-6) PTCORD-6
IEC60320/C19 to L5-20P, 10'(PTCORD-7) PTCORD-7
IEC 60320/C13 to IEC 60320/C14, 7'(PTCORDPK-1) PTCORDPK-1
IEC 60320/C13 to IEC 60320/C14, 7'(PTCORD-PK-2) PTCORDPK-2
 