ServerTechnology Mid-Density Metered Power Distribution
(C-10H1-L530) |
|

ServerTechnology Mid-Density
Metered Power Distribution C-10H1-L530
|

|
ServerTech (C-10H1-L530) CDU Mid-Density Metered Power Distribution
Increasing power demands and density in the equipment cabinet
requires new functionality from your cabinet ServerTech's (C-10H1-L530)
Sentry CDU product family uniquely meets these demands. ServerTech's
(C-10H1-L530) Sentry Cabinet Power Distribution Unit (CDU) is
an intelligent PDU with local LED input current monitoring,
allowing network engineers to utilize the CDU’s True RMS Power
Monitor to precisely measure the current (in amps) that network
devices are drawing on the power circuit. As new servers and
devices are added to the power drop, immediately observe its
impact on the cumulative current draw. This allows the engineer
to safely load each circuit to its maximum allowable load capacity
without the danger of overloading the power circuit.
ServerTech Mid-Density Metered Power Distribution C-10H1-L530
Features & Benefits:
- Branch Current Monitoring: The CDU’s exclusive
True RMS current monitoring is critical to preventing overloads
in high density computing environments. LED digital displays
are accesible through IP-access to report the input current
of each phase or branch circuit.
- Branch Circuit Protection: The Sentry CDU
Family meets the new UL 60950-1 requirement for branch circuit
protection.
ServerTech Mid-Density Metered Power Distribution C-10H1-L530
Specifications:
| |
| C-10H
|
|
C-10H1-C20 |
100-120V 50/60Hz |
20/30A |
IEC 60320/C20 Power Inlet
|
(10) NEMA 5-20R |
1.75" (H)
17.0"W, 10"D |
|
C-10H1-L530 |
100-120V 50/60Hz |
20/30A |
NEMA L5-30P Cordset
|
(10) NEMA 5-20R |
1.75" (H)
17.0"W, 10"D |
|
C-12H2-C20 |
208-240V 60Hz |
20/30A |
IEC 60320/C20 Power Inlet
|
(12) IEC 60320/C13
|
1.75" (H)
17.0"W, 10"D |
|
C-12H2-L630 |
208-240V 60Hz |
20/30A |
NEMA L6-30P Cordset
|
(12) IEC 60320/C13
|
1.75" (H)
17.0"W, 10"D |
|
|
| |
| IEC 60320/C19 to
L6-20P, 10' (PTCORD-1) |
PTCORD-1 |
| IEC 60320/C19 to
Schuko, 10' (PTCORD-2) |
PTCORD-2 |
| IEC 60320/C19 to
IEC 60309 (BS4343, CEE17) 16/20A Blue (PTCORD-3) |
PTCORD-3 |
| IEC 60320/C19 to
BS1363 13A (UK), 10' (PTCORD-4) |
PTCORD-4 |
| IEC60320/C19 to 5-15P
, 10' (PTCORD-5) |
PTCORD-5 |
| IEC60320/C19 to 5-20P,
10' (PTCORD-6) |
PTCORD-6 |
| IEC60320/C19 to L5-20P,
10' (PTCORD-7) |
PTCORD-7 |
| IEC 60320/C13 to
IEC 60320/C14, 7' (PTCORDPK-1) |
PTCORDPK-1 |
| IEC 60320/C13 to
IEC 60320/C14, 7' (PTCORD-PK-2) |
PTCORDPK-2 |
|
|
|