ServerTechnology Mid-Density Metered Power Distribution (C-10H1-C20) |
 ServerTechnology Mid-Density Metered Power Distribution C-10H1-C20
| 
|
ServerTech CDU Mid-Density Metered Power Distribution (C-10H1-C20) Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU. ServerTech's (C-10H1-C20) Sentry CDU product family uniquely meets these demands. ServerTech's (C-10H1-C20) Sentry Cabinet Power Distribution Unit (CDU) is an intelligent PDU with local LED input current monitoring, allowing network engineers to utilize the CDU’s True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new servers and devices are added to the power drop, immediately observe its impact on the cumulative current draw. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit. ServerTech Mid-Density Metered Power Distribution C-10H1-C20 Features & Benefits: - Branch Current Monitoring: The CDU’s exclusive True RMS current monitoring is critical to preventing overloads in high density computing environments. LED digital displays are accesible through IP-access to report the input current of each phase or branch circuit.
- Branch Circuit Protection: The Sentry CDU Family meets the new UL 60950-1 requirement for branch circuit protection.
ServerTech Mid-Density Metered Power Distribution C-10H1-C20 Specifications: | | |
| C-10H | | C-10H1-C20 | 100-120V 50/60Hz | 20/30A | IEC 60320/C20 Power Inlet | (10) NEMA 5-20R | 1.75" (H) 17.0"W, 10"D | | C-10H1-L530 | 100-120V 50/60Hz | 20/30A | NEMA L5-30P Cordset | (10) NEMA 5-20R | 1.75" (H) 17.0"W, 10"D | | C-12H2-C20 | 208-240V 60Hz | 20/30A | IEC 60320/C20 Power Inlet | (12) IEC 60320/C13 | 1.75" (H) 17.0"W, 10"D | | C-12H2-L630 | 208-240V 60Hz | 20/30A | NEMA L6-30P Cordset | (12) IEC 60320/C13 | 1.75" (H) 17.0"W, 10"D |
| | | | |
| IEC 60320/C19 to L6-20P, 10' (PTCORD-1) | PTCORD-1 | | IEC 60320/C19 to Schuko, 10' (PTCORD-2) | PTCORD-2 | | IEC 60320/C19 to IEC 60309 (BS4343, CEE17) 16/20A Blue (PTCORD-3) | PTCORD-3 | | IEC 60320/C19 to BS1363 13A (UK), 10' (PTCORD-4) | PTCORD-4 | | IEC60320/C19 to 5-15P , 10' (PTCORD-5) | PTCORD-5 | | IEC60320/C19 to 5-20P, 10' (PTCORD-6) | PTCORD-6 | | IEC60320/C19 to L5-20P, 10' (PTCORD-7) | PTCORD-7 | | IEC 60320/C13 to IEC 60320/C14, 7' (PTCORDPK-1) | PTCORDPK-1 | | IEC 60320/C13 to IEC 60320/C14, 7' (PTCORD-PK-2) | PTCORDPK-2 |
| |
|