Sentry Switched CDU 32V
Switched Power Control via IP, 32
outlets with LED input current displays, branch circuit
protection and IP monitoring ; mid-density.
The Switched CDU combines remote configuration
and management with power distribution, power monitoring
and environmental monitoring. Reboot a single or dual-power
server with one command. Receive SNMP alerts when power
or environmental conditions exceed thresholds. Assign
users specific access rights to designated outlets or
groups.
Only the Switched CDU products provide
the flexibility needed for all data centers and remote
sites, including power requirements for high-amp, high
voltage; UL 60950-1 branch circuit protection; SSL &
SSH security; and SNMP-based input current monitoring.
The Switched CDU also supports Enterprise
View PDU Manager. This gives the engineer the ability
to manage a large installation of Networked CDUs from
one location, view and access up to 1,000 Switched CDUs
from a single web interface.

Sentry Switched CDU 32V Product Details:
Sentry Switched CDU 32V SSL Web Browser:
Secure Sockets Layer (SSL) is a commonly-used protocol
for managing the security of a message transmission
on the Internet. SSL is an integral part of most Web
browsers (clients) and Web servers. Sentry supports
SSLv3/TLSv1.
Sentry Switched CDU 32V HTTP/HTTPs
Web Configuration & Control: Use the Sentry Web
interface to configure each unit, including network
settings, outlet naming & grouping, SNMP traps for environmental
& power thresholds and firmware updates. Also use the
Web interface to control individual or group outlets
and monitor environmental conditions. SSL security provides
a secure HTTPs connection.
Sentry Switched CDU 32V Remote Outlet
Grouping & Control: Assign outlets to a group for
control of dual-power supply servers and other gear
with a single command. Create an unlimited number of
groups with any combination of outlets associated to
each group.
Sentry Switched CDU 32V SSH Management:
Secure Shell (SSH), sometimes known as Secure Socket
Shell, is a Unix-based command interface and protocol
for securely getting access to a remote device. Sentry
supports SSHv2.
Sentry Switched CDU 32V SNMP Management:
The Sentry family of products supports the Simple Network
Management Protocol (SNMP). This allows network management
systems to use SNMP requests to retrieve information
and control power for the individual outlets. The Sentry
includes an SNMP v1 agent supporting standard MIB I
and MIB II objects. A private enterprise MIB extension
(Sentry3 MIB) is also supported to provide remote power
control.
Sentry Switched CDU 32V LDAP: LDAP (Lightweight
Directory Access Protocol) is a software protocol for
enabling anyone to locate organizations, individuals,
and other resources such as files and devices in a network,
whether on the public Internet or on a corporate intranet.
Sentry firmware code 5.3b and newer includes support
for LDAP v3 and is configurable to operate with any
Directory Service. It has been tested with these Directory
Services:
Sentry Switched CDU 32V RS-232 Control:
Serial control via any device with a bi-directional
serial port, including a PC, laptop, KVM switch, Console
Port Access switch, or terminal server.
Sentry Switched CDU 32V Telnet Management:
Telnet is a user command and an underlying TCP/IP protocol
for accessing remote computers.
Sentry Switched CDU 32V SNMP Traps
for Event Notification: SNMP traps can be generated
for various events, including Input Current Load Thresholds
(min & max), Temperature Thresholds (min & max), Humidity
Thresholds (min & max), water indication, closed contacts
(cabinet doors open/close), as well as notification
of any time an outlet status is changed (on/off).
Sentry Switched CDU 32V Power-Up
Sequencing: Prevent a power in-rush from overloading
the power circuit. In the event of a power loss, this
key feature prevents all power-outlet receptacles from
powering on at once - averting the potential for a power
in-rush to blow a fuse or circuit breaker in the data
center. Instead, the power-outlet receptacles power-on
in two-second intervals, allowing each device to safely
boot-up. Power-up sequencing is a default hardware setting.
User adjustable.
Sentry Switched CDU 32V True RMS
Input Current Monitoring: Input Current Monitoring
in Sentry power products is reported as the cumulative
load (in amps) on each power circuit so that data center
managers can obtain the data they need to plan their
power requirements and to monitor power to their IT
equipment. Input Current is reported in Amps and can
be viewed locally on the enclosure via an LED Digital
Display and remotely, when applicable, via the firmware
interface.
Sentry Switched CDU 32V High-amp
In-rush Protection: High-Amp In-rush relays accommodate
the extremely high power in-rush spikes from today’s
switching power supplies.
Sentry Switched CDU 32V Multiple
Concurrent Users: Multiple concurrent users allows
several users to be logged into a Sentry at the same
time. In this way, different users, with access rights
to only their equipment, can reboot their device(s)
when they need to, without waiting for another user
to log out of the Sentry unit.
Sentry Switched CDU 32V 24-character
Outlet Receptacles Names: Use the firmware interface
(Web or serial) to edit individual outlet receptacles.
Identify each receptacle with the device's serial number,
IP address, asset allocation #, department or any other
method to individually name outlets.
Sentry Switched CDU 32V 20-Amp Power
Input Support: 20-amp Power Input Support. IEC320/C20
power inlet receptacles supports any power cord with
IEC320/C19 power connector (PTCORD-XX).
Sentry Switched CDU 32V 30-Amp Power
Input Support: 30-amp Power Input Support. Hard-wired
with 10' cord and appropriate L5-30 or L6-30 plug type.
Sentry Switched CDU 32V Zero U Enclosure:
A vertical enclosure that occupies Zero Vertical
U of rack space in the equipment cabinet. It mounts
on the back rails or in the cavity space of the cabinet.
Sentry Switched CDU 32V LED Digital
Display Input Current Monitor: Easy viewing display
on the face of the enclosure that reports the True RMS
Power Monitoring of the aggregate load on the power
circuit (in amps). The Input Current Display allows
installation engineers to verify the real-time current
draw on the power circuit. This eliminates the guesswork
of estimating the current draw and prevents the costly
mistake of: 1) overestimating and requiring extra power
drops installed or 2) underestimating and overloading
a circuit - putting the enter cabinet at risk if a circuit
breaker at the main PDU trips.
Sentry Switched CDU 32V Integrate
Environmental Monitoring: The EMCU integrates easily
with the Power Tower XL, or other Sentry Remote Power
Manager. Locate the EMCU in an equipment cabinet with
a PTXL, link it to the PTXL and view temperature, humidity,
water sensing and dry contact closures from the same
PTXL interface you use to manage & monitor the power.
Sentry Switched CDU 32V Authentication:
16-character Username & Password required for network
administrators & user accounts. Multiple user accounts
can be established with access rights only to designated
outlets.
Sentry Switched CDU 32V Branch Circuit
Protection: Sentry PDUs are safety-agency certified
to the new UL 60950-1 standard (CSA/UL/TUV) & the National
Electrical Code (NEC), which require branch circuit
protection for receptacles.
Sentry Switched CDU 32V Firmware
Flash Upgradeable: Access new firmware updates via
FTP for new firmware features and code releases. An
update to the firmware does not affect the status of
the power outlets.
Sentry Switched CDU 32V Remote Individual
Outlet control: Reduce Mean Time to Repair
(MTTR) of a failing server by controlling individual
power outlet receptacles to reboot any selected server
or other device.
Sentry Switched CDU 32V Always-On Outlets:
Outlets are powered-on in their default state. User
action is required to perform a power-off or reboot
to change the status of each power outlet receptacle's
relay.
Sentry Switched CDU 32V Integrated
Temp/Humidity Probes: Two (2) RJ-style connectors
located on the face panel of the PDU's enclosure provide
support for two (2) Integrated Temperature & Humidity
Probes with six-foot (6') cables provide real-time measurements
in the data center cabinet.
Sentry Switched CDU 32V HTTP/HTTPs
Web Monitoring: Use the Web interface to access
and monitor key values, including amperage load(s),
temperature/humidity and other environmental factors.
Sentry Switched CDU 32V Fuse-protected
outlets: Power Outlet protection provided
by fuses.
Sentry Switched CDU 32V EV-200:
Enterprise View 200 auto discovers up to 200 Sentry
devices.
Sentry Switched CDU 32V EV-1K:
Enterprise View 1K auto discovers up to 1,000 Sentry
Devices
Sentry Switched CDU 32V Remote Power
Control: Individual or group outlet remote
power control to cycle power and reboot any selected
server(s) or other network device(s). Use TCP/IP (HTTP,
HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with
each Sentry and rectify locked-up network devices.
|
Sentry Switched
CDU 32V Specifications |
|
Item # |
Available Input
Voltages |
Rated Amperage |
Available Input
Cord |
Outlets |
Dimensions |
|
CW-32V |
|
CW-32VD1-C20 |
100-120V
50-60Hz |
20/30A |
IEC 60320/C20
Power Inlet |
(32) NEMA
5-20R |
63.5” (L)
3.5" (W)
2.25” (D) |
|
CW-32VD1-L530 |
100-120V
50-60Hz |
20/30A |
NEMA L5-30P
Cordset |
(32) NEMA
5-20R |
63.5” (L)
3.5" (W)
2.25” (D) |
|
CW-32VD2-C20 |
208-240V
60Hz |
20/30A |
IEC 60320/C20
Power Inlet |
(32) IEC
60320/C13 |
63.5” (L)
3.5" (W)
2.25” (D) |
|
CW-32VD2-L630 |
208-240V
60Hz |
20/30A |
NEMA L6-30P
Cordset |
(32) IEC
60320/C13 |
63.5” (L)
3.5" (W)
2.25” (D) |
|
CW-32VDE-C20 |
230V
50/60Hz |
20/30A |
IEC 60320/C20
Power Inlet |
(32) IEC
60320/C13 |
63.5” (L)
3.5" (W)
2.25” (D) |
|
Power Cord Options |
|
> PTCORD-1
IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock)
10’
> PTCORD-2 IEC 60320/C19 - Schuko 10’
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343,
CEE17) 16/20A Blue (UK Commando) 10’
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK)
10’
> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade)
10’
> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade)
10’
> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock)
10’
> PT-ADP-C19 Cable mount IEC 60320/C19 Connector
|
|
Technical Specs |
|
Standards
> CTUVus – UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> TUV_GS – EN60950-1:2001
Communications
> 10/100 BaseT Ethernet
> SSLv3/TLSv1
> SNMPv2
Accessories
> Temperature & Humidity Probe Option
|
ServerTech Sentry Switched CDU 32V Downloads & Manuals