Sentry CDU-16V
Switched Power Control via IP, 16
outlets with LED input current displays, branch circuit
protection and IP monitoring ; mid-density.
| The Switched CDU combines remote
configuration and management with power distribution,
power monitoring and environmental monitoring.
Reboot a single or dual-power server with one
command. Receive SNMP alerts when power or environmental
conditions exceed thresholds. Assign users specific
access rights to designated outlets or groups.
Only the Switched CDU products provide the flexibility
needed for all data centers and remote sites,
including power requirements for high-amp, high
voltage; UL 60950-1 branch circuit protection;
SSL & SSH security; and SNMP-based input current
monitoring. The Switched CDU also supports
Enterprise View PDU Manager. This gives the
engineer the ability to manage a large installation
of Networked CDUs from one location, view and
access up to 1,000 Switched CDUs from a single
web interface.
|

Switched CDU 16V
|

Sentry CDU-16V Product Details:
Sentry CDU-16V SSL Web Browser:
Secure Sockets Layer (SSL) is a commonly-used protocol
for managing the security of a message transmission
on the Internet. SSL is an integral part of most Web
browsers (clients) and Web servers. Sentry supports
SSLv3/TLSv1.
Sentry CDU-16V HTTP/HTTPs Web Configuration
& Control: Use the Sentry Web interface to configure
each unit, including network settings, outlet naming
& grouping, SNMP traps for environmental & power thresholds
and firmware updates. Also use the Web interface to
control individual or group outlets and monitor environmental
conditions. SSL security provides a secure HTTPs connection.
Sentry CDU-16V Remote Outlet Grouping
& Control: Assign outlets to a group for control
of dual-power supply servers and other gear with a single
command. Create an unlimited number of groups with any
combination of outlets associated to each group.
Sentry CDU-16V SSH Management:
Secure Shell (SSH), sometimes known as Secure Socket
Shell, is a Unix-based command interface and protocol
for securely getting access to a remote device. Sentry
supports SSHva2.
Sentry CDU-16V SNMP Management:
The Sentry family of products supports the Simple Network
Management Protocol (SNMP). This allows network management
systems to use SNMP requests to retrieve information
and control power for the individual outlets. The Sentry
includes an SNMP v1 agent supporting standard MIB I
and MIB II objects. A private enterprise MIB extension
(Sentry3 MIB) is also supported to provide remote power
control.
Sentry CDU-16V LDAP: LDAP (Lightweight Directory
Access Protocol) is a software protocol for enabling
anyone to locate organizations, individuals, and other
resources such as files and devices in a network, whether
on the public Internet or on a corporate intranet.
Sentry firmware code 5.3b and newer includes support
for LDAP v3 and is configurable to operate with any
Directory Service. It has been tested with these Directory
Services:
Sentry CDU-16V RS-232 Control:
Serial control via any device with a bi-directional
serial port, including a PC, laptop, KVM switch, Console
Port Access switch, or terminal server.
Sentry CDU-16V Telnet Management:
Telnet is a user command and an underlying TCP/IP protocol
for accessing remote computers.
Sentry CDU-16V SNMP Traps for Event
Notification: SNMP traps can be generated for various
events, including Input Current Load Thresholds (min
& max), Temperature Thresholds (min & max), Humidity
Thresholds (min & max), water indication, closed contacts
(cabinet doors open/close), as well as notification
of any time an outlet status is changed (on/off).
Sentry CDU-16V Power-Up Sequencing:
Prevent a power in-rush from overloading the power circuit.
In the event of a power loss, this key feature prevents
all power-outlet receptacles from powering on at once
- averting the potential for a power in-rush to blow
a fuse or circuit breaker in the data center. Instead,
the power-outlet receptacles power-on in two-second
intervals, allowing each device to safely boot-up. Power-up
sequencing is a default hardware setting. User adjustable.
Sentry CDU-16V True RMS Input Current
Monitoring: Input Current Monitoring in Sentry power
products is reported as the cumulative load (in amps)
on each power circuit so that data center managers can
obtain the data they need to plan their power requirements
and to monitor power to their IT equipment. Input Current
is reported in Amps and can be viewed locally on the
enclosure via an LED Digital Display and remotely, when
applicable, via the firmware interface.
Sentry CDU-16V High-amp In-rush Protection:
High-Amp In-rush relays accommodate the extremely high
power in-rush spikes from today's switching power supplies.
Sentry CDU-16V Multiple Concurrent
Users: Multiple concurrent users allows several
users to be logged into a Sentry at the same time. In
this way, different users, with access rights to only
their equipment, can reboot their device(s) when they
need to, without waiting for another user to log out
of the Sentry unit.
Sentry CDU-16V 24-character Outlet
Receptacles Names: Use the firmware interface (Web
or serial) to edit individual outlet receptacles. Identify
each receptacle with the device's serial number, IP
address, asset allocation #, department or any other
method to individually name outlets.
Sentry CDU-16V 20-Amp Power Input
Support: 20-amp Power Input Support. IEC320/C20
power inlet receptacles supports any power cord with
IEC320/C19 power connector (PTCORD-XX).
Sentry CDU-16V 30-Amp Power Input
Support: 30-amp Power Input Support. Hard-wired
with 10'cord and appropriate L5-30 or L6-30 plug type.
Sentry CDU-16V Zero U Enclosure:
A vertical enclosure that occupies Zero Vertical
U of rack space in the equipment cabinet. It mounts
on the back rails or in the cavity space of the cabinet.
Sentry CDU-16V LED Digital Display
Input Current Monitor: Easy viewing display on the
face of the enclosure that reports the True RMS Power
Monitoring of the aggregate load on the power circuit
(in amps). The Input Current Display allows installation
engineers to verify the real-time current draw on the
power circuit. This eliminates the guesswork of estimating
the current draw and prevents the costly mistake of:
1) overestimating and requiring extra power drops installed
or 2) underestimating and overloading a circuit - putting
the enter cabinet at risk if a circuit breaker at the
main PDU trips.
Sentry CDU-16V Integrate Environmental
Monitoring: The EMCU integrates easily with the
Power Tower XL, or other Sentry Remote Power Manager.
Locate the EMCU in an equipment cabinet with a PTXL,
link it to the PTXL and view temperature, humidity,
water sensing and dry contact closures from the same
PTXL interface you use to manage & monitor the power.
Sentry CDU-16V Authentication:
16-character Username & Password required for network
administrators & user accounts. Multiple user accounts
can be established with access rights only to designated
outlets.
Sentry CDU-16V Branch Circuit Protection:
Sentry PDUs are safety-agency certified to the new
UL 60950-1 standard (CSA/UL/TUV) & the National Electrical
Code (NEC), which require branch circuit protection
for receptacles.
Sentry CDU-16V Firmware Flash Upgradeable:
Access new firmware updates via FTP for new firmware
features and code releases. An update to the firmware
does not affect the status of the power outlets.
Sentry CDU-16V Remote Individual
Outlet control: Reduce Mean Time to Repair
(MTTR) of a failing server by controlling individual
power outlet receptacles to reboot any selected server
or other device.
Sentry CDU-16V Always-On Outlets: Outlets
are powered-on in their default state. User action is
required to perform a power-off or reboot to change
the status of each power outlet receptacle's relay.
Sentry CDU-16V Integrated Temp/Humidity
Probes: Two (2) RJ-style connectors located on the
face panel of the PDU's enclosure provide support for
two (2) Integrated Temperature & Humidity Probes with
six-foot (6') cables provide real-time measurements
in the data center cabinet.
Sentry CDU-16V HTTP/HTTPs Web Monitoring:
Use the Web interface to access and monitor key
values, including amperage load(s), temperature/humidity
and other environmental factors.
Sentry CDU-16V Fuse-protected outlets:
Power Outlet protection provided by fuses.
Sentry CDU-16V EV-200:
Enterprise View 200 auto discovers up to 200 Sentry
devices.
Sentry CDU-16V EV-1K: Enterprise
View 1K auto discovers up to 1,000 Sentry Devices
Sentry CDU-16V Remote Power Control:
Individual or group outlet remote power control
to cycle power and reboot any selected server(s) or
other network device(s). Use TCP/IP (HTTP, HTTPS, SSH,
Telnet, SNMP) or RS-232 to communicate with each Sentry
and rectify locked-up network devices.
|
Sentry CDU-16V
Specifications |
|
Item # |
Available Input
Voltages |
Rated Amperage |
Available Input
Cord |
Outlets |
Dimensions |
|
CW-16V |
|
CW-16V1-L530 |
100-120V
50-60Hz |
20/30A |
NEMA L5-30P
Cordset |
(16) NEMA
5-20R |
63.5" (L)
1.75" (W)
2.25" (D) |
|
CW-16V2-C20 |
208-240V
60Hz |
20/30A |
IEC 60320/C20
Power Inlet |
(16) IEC
60320/C13 |
63.5" (L)
1.75" (W)
2.25" (D) |
|
CW-16V2-L630 |
208-240V
60Hz |
20/30A |
NEMA L6-30P
Cordset |
(16) IEC
60320/C13 |
63.5" (L)
1.75" (W)
2.25" (D) |
|
CW-16VE-C20 |
230V
50-60Hz |
20/30A |
IEC 60320/C20
Power Inlet |
(16) IEC
60320/C13 |
63.5" (L)
1.75" (W)
2.25" (D) |
|
Power Cord Options |
|
> PTCORD-1
IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock)
10'> PTCORD-2 IEC 60320/C19 - Schuko 10'> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343,
CEE17) 16/20A Blue (UK Commando) 10'> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK)
10'> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade)
10'> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade)
10'> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock)
10'> PT-ADP-C19 Cable mount IEC 60320/C19 Connector
|
|
Technical Specs |
|
Standards
> CTUVus - UL 60950-1-2003
> CAN/CSA 22.2 No. 60950-1:2003
> TUV_GS - EN60950-1:2001
Communications
> 10/100 BaseT Ethernet
> SSLv3/TLSv1
> SNMPv2
Accessories
> Temperature & Humidity Probe Option, EMTH-1-1
Temperature & Humidity Probe, 10'
|
ServerTech Sentry CDU-16V Downloads & Manuals