Sentry provides 3-phase power distribution with mixed voltage output.
A typical dense-server data center will deploy equipment cabinets containing 42 1U dual-power supply servers in each cabinet. Power demands for this cabinet far exceed a single-phase 120V 20A power circuit. The Sentry CDU with its dual power feeds and its 84 outlet receptacles provides capacity to support at total of 42 1U dual-power supply servers in a single cabinet.

Focusing on this requirement, two new Sentry CDU models meet these requirements by providing 10kW or 20kW of power distribution.

Beyond its high-power distribution capabilities, the Sentry CDU has many exclusive features:

  • High-density Equipment Cabinet Power Distribution
  • 54-outlet receptacles
  • True RMS Power Monitoring per branch circuit/phase
  • Power Meters Facilitate Load Balancing
  • Power display meters on the CDU enclosure
  • Remote IP access for power displays
  • Secure Web Interface
  • SNMP MIB & Traps
  • Integrated Temperature & Humidity Probes
  • Exclusive "Notch" straddles Center Rail for flush mounting to the interior of the equipment cabinet
  • EN-60950-1 Compliant
  • Sentry Smart CDU-54-DY Key Features & Benefits

Sentry Smart CDU-54-DY True RMS Input Current Monitoring: Input Current Monitoring in Sentry power products is reported as the cumulative load (in amps) on each power circuit so that data center managers can obtain the data they need to plan their power requirements and to monitor power to their IT equipment. Input Current is reported in Amps and can be viewed locally on the enclosure via an LED Digital Display and remotely, when applicable, via the firmware interface.

Sentry Smart CDU-54-DY SSL Web Browser:
Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.

Sentry Smart CDU-54-DY SNMP Management:
The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information and control power for the individual outlets. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control.
Sentry Smart CDU-54-DY SNMP Traps for Event Notification: SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, closed contacts (cabinet doors open/close), as well as notification of any time an outlet status is changed (on/off).

Sentry Smart CDU-54-DY Authentication:
16-character Username & Password required for network administrators & user accounts. Multiple user accounts can be established with access rights only to designated outlets.

Sentry Smart CDU-54-DY LED Digital Display Input Current Monitor: Easy viewing display on the face of the enclosure that reports the True RMS Power Monitoring of the aggregate load on the power circuit (in amps). The Input Current Display allows installation engineers to verify the real-time current draw on the power circuit. This eliminates the guesswork of estimating the current draw and prevents the costly mistake of: 1) overestimating and requiring extra power drops installed or 2) underestimating and overloading a circuit - putting the enter cabinet at risk if a circuit breaker at the main PDU trips.
Sentry Smart CDU-54-DY 20-Amp Power Input Support: 20-amp Power Input Support. IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX).
Sentry Smart CDU-54-DY 30-Amp Power Input Support: 30-amp Power Input Support. Hard-wired with 10'cord and appropriate L5-30 or L6-30 plug type.

Sentry Smart CDU-54-DY Zero U Enclosure: A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.
Sentry Smart CDU-54-DY Branch Circuit Protection: Sentry PDUs are safety-agency certified to the new UL 60950-1 standard (CSA/UL/TUV) & the National Electrical Code (NEC), which require branch circuit protection for receptacles.

Sentry Smart CDU-54-DY Firmware Flash Upgradeable:
 Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.

Sentry Smart CDU-54-DY Integrated Temp/Humidity Probes: Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with six-foot (6') cables provide real-time measurements in the data center cabinet.

Sentry Smart CDU-54-DY HTTP/HTTPs Web Monitoring: Use the Web interface to access and monitor key values, including amperage load(s), temperature/humidity and other environmental factors.

 
 
Item # Available Input
Voltages
Rated Amperage Available Input Cord Outlets Dimensions
CS-54VDY-L2120 3-Phase, Delta 208V
60Hz
20/30A NEMA L21-20P
Cordset
(12) NEMA 5-20R
(42) IEC 60320/C13
66.0"L, 3.5"W, 2.25"D
CS-54VDY-L2130 3-Phase, Wye 208V
60Hz
20/30A NEMA L21-30P
Cordset
(12) NEMA 5-20R
(42) IEC 60320/C13
66.0"L, 3.5"W, 2.25"D
 
     
 
ServerTech Power Cord Options Part Number
IEC 60320/C19 to L6-20P, 10'(PTCORD-1) PTCORD-1
IEC 60320/C19 to Schuko, 10'(PTCORD-2) PTCORD-2
IEC 60320/C19 to IEC 60309 (BS4343, CEE17) 16/20A Blue (PTCORD-3) PTCORD-3
IEC 60320/C19 to BS1363 13A (UK), 10'(PTCORD-4) PTCORD-4
IEC60320/C19 to 5-15P , 10'(PTCORD-5) PTCORD-5
IEC60320/C19 to 5-20P, 10'(PTCORD-6) PTCORD-6
IEC60320/C19 to L5-20P, 10'(PTCORD-7) PTCORD-7
IEC 60320/C13 to IEC 60320/C14, 7'(PTCORDPK-1) PTCORDPK-1
IEC 60320/C13 to IEC 60320/C14, 7'(PTCORD-PK-2) PTCORDPK-2
 
     

 Home About 42U Careers Clients Vendors Press Articles Efficiency Glossary Site Map Efficiency Calculator
Data Center Solutions UPS Power Data Center Efficiency Efficiency Services Rack Accessories Efficiency Best Practices Lights Out
Follow us on:
 Follow 42u on Twitter Subscribe to 42U's channel on YouTube View 42u's profile on slideshare

Sentry Smart CDU