Sentry CDU-54-DY

Sentry Smart CDU-54-DY
Sentry provides 3-phase power distribution
with mixed voltage output.
A typical dense-server data center will deploy
equipment cabinets containing 42 1U dual-power
supply servers in each cabinet. Power demands for
this cabinet far exceed a single-phase 120V 20A
power circuit. The Sentry CDU with its dual power
feeds and its 84 outlet receptacles provides
capacity to support at total of 42 1U dual-power
supply servers in a single cabinet.
Focusing on this requirement, two new Sentry CDU
models meet these requirements by providing 10kW or
20kW of power distribution.
Beyond its high-power distribution capabilities,
the Sentry CDU has many exclusive features:
- High-density Equipment Cabinet Power
Distribution
- 54-outlet receptacles
- True RMS Power Monitoring per branch
circuit/phase
- Power Meters Facilitate Load Balancing
- Power display meters on the CDU enclosure
- Remote IP access for power displays
- Secure Web Interface
- SNMP MIB & Traps
- Integrated Temperature & Humidity Probes
- Exclusive "Notch" straddles Center Rail for
flush mounting to the interior of the equipment
cabinet
- EN-60950-1 Compliant
- Sentry Smart CDU-54-DY Key Features &
Benefits
Sentry Smart CDU-54-DY True RMS Input Current
Monitoring: Input Current Monitoring in Sentry power
products is reported as the cumulative load (in
amps) on each power circuit so that data center
managers can obtain the data they need to plan their
power requirements and to monitor power to their IT
equipment. Input Current is reported in Amps and can
be viewed locally on the enclosure via an LED
Digital Display and remotely, when applicable, via
the firmware interface.
Sentry Smart CDU-54-DY SSL Web Browser:
Secure Sockets Layer (SSL) is a commonly-used
protocol for managing the security of a message
transmission on the Internet. SSL is an integral
part of most Web browsers (clients) and Web servers.
Sentry supports SSLv3/TLSv1.
Sentry Smart CDU-54-DY SNMP Management:
The Sentry family of products supports the
Simple Network Management Protocol (SNMP). This
allows network management systems to use SNMP
requests to retrieve information and control power
for the individual outlets. The Sentry includes an
SNMP v1 agent supporting standard MIB I and MIB II
objects. A private enterprise MIB extension (Sentry3
MIB) is also supported to provide remote power
control.
Sentry Smart CDU-54-DY SNMP Traps for Event
Notification: SNMP traps can be generated for
various events, including Input Current Load
Thresholds (min & max), Temperature Thresholds (min
& max), Humidity Thresholds (min & max), water
indication, closed contacts (cabinet doors
open/close), as well as notification of any time an
outlet status is changed (on/off).
Sentry Smart CDU-54-DY Authentication:
16-character Username & Password required for
network administrators & user accounts. Multiple
user accounts can be established with access rights
only to designated outlets.
Sentry Smart CDU-54-DY LED Digital Display Input
Current Monitor: Easy viewing display on the face of
the enclosure that reports the True RMS Power
Monitoring of the aggregate load on the power
circuit (in amps). The Input Current Display allows
installation engineers to verify the real-time
current draw on the power circuit. This eliminates
the guesswork of estimating the current draw and
prevents the costly mistake of: 1) overestimating
and requiring extra power drops installed or 2)
underestimating and overloading a circuit - putting
the enter cabinet at risk if a circuit breaker at
the main PDU trips.
Sentry Smart CDU-54-DY 20-Amp Power Input Support:
20-amp Power Input Support. IEC320/C20 power inlet
receptacles supports any power cord with IEC320/C19
power connector (PTCORD-XX).
Sentry Smart CDU-54-DY 30-Amp Power Input Support:
30-amp Power Input Support. Hard-wired with 10'cord
and appropriate L5-30 or L6-30 plug type.
Sentry Smart CDU-54-DY Zero U Enclosure: A
vertical enclosure that occupies Zero Vertical U of
rack space in the equipment cabinet. It mounts on
the back rails or in the cavity space of the
cabinet.
Sentry Smart CDU-54-DY Branch Circuit Protection:
Sentry PDUs are safety-agency certified to the new
UL 60950-1 standard (CSA/UL/TUV) & the National
Electrical Code (NEC), which require branch circuit
protection for receptacles.
Sentry Smart CDU-54-DY Firmware Flash
Upgradeable:
Access new firmware updates via FTP for
new firmware features and code releases. An update
to the firmware does not affect the status of the
power outlets.
Sentry Smart CDU-54-DY Integrated Temp/Humidity
Probes: Two (2) RJ-style connectors located on the
face panel of the PDU's enclosure provide support
for two (2) Integrated Temperature & Humidity Probes
with six-foot (6') cables provide real-time
measurements in the data center cabinet.
Sentry Smart CDU-54-DY HTTP/HTTPs Web Monitoring:
Use the Web interface to access and monitor key
values, including amperage load(s),
temperature/humidity and other environmental
factors. |