ServerTech CDU-24V4 Metered Power Distribution

ServerTech CDU-24V4
NOTE: This products is coming soon!
ServerTech CDU-24V4 Power Distribution
High Power Distribution: 400V, three-phase power; 20 or
30-Amp power input feed options with 208V output
The Switched CDU's combine remote configuration and management
with power distribution and power and environmental monitoring.
Reboot a single or dual-power server with one command. Receive
SNMP alerts when power or environmental conditions exceed thresholds.
Assign users specific access rights to designated outlets or
groups. Only the Switched CDU products provide the flexibility
needed for all data centers and remote sites, including power
requirements for high-amp, high voltage; UL 60950-1 branch circuit
protection; SSL & SSH security; and SNMP-based input current
monitoring.The Switched CDU also supports Enterprise View PDU
Manager. This gives the engineer the ability to manage a large
installation of Networked CDUs from one location, view and access
up to 1,000 Switched CDUs from a single web interface.
ServerTech's CDU-24V4 Sentry CDU product family uniquely
meets these demands. ServerTech's CDU-24V4 Sentry Cabinet Power
Distribution Unit (CDU) is an intelligent PDU with local LED
input current monitoring, allowing network engineers to utilize
the CDU's True RMS Power Monitor to precisely measure the current
(in amps) that network devices are drawing on the power circuit.
As new servers and devices are added to the power drop, immediately
observe its impact on the cumulative current draw. This allows
the engineer to safely load each circuit to its maximum allowable
load capacity without the danger of overloading the power circuit.
ServerTech CDU-24V4 Features:
- Branch Circuit Protection: The Sentry CDU Family
meets the new UL 60950-1 requirement for branch circuit
protection. Attention! The Sentry CDU products meet the
above criteria by providing overcurrent protection with
UL-listed Bussman SC fuses for each branch circuit.
- Branch Current Monitoring: The CDU's exclusive
True RMS current monitoring is critical to preventing overloads
in high-density computing environments. LED digital displays
on the CDU enclosure report the input current of each phase
or branch circuit.
- Button Mounting: All CDUs are also compatible
with new button & "keyhole" style mounting for cabinets.
Several cabinet manufacturers are now using this method
for installing power distribution units in the cabinet.
- Cabinet Power Distribution: Reliable single &
three-phase power distribution for all the devices in your
equipment cabinet. Choose a single or dual-power feed model
to run all power cables to one side of the cabinet -- leaving
the other side open for data cable management
ServerTech CDU-24V4 Smart Power Distribution Specifications:
| |
|
CS-24V2-L630
|
208-240V
60Hz
|
20/30A
|
NEMA L6-30P
Cordset
|
(24) IEC 60320/C13
|
63.5"
1.75"
2.25"
|
|
CS-24VD-L1520
|
3-Phase, Delta 240V, 60Hz
|
20/30A
|
NEMA L1520
Cordset
|
(24) IEC 60320/C13
|
63.5"
1.75"
2.25"
|
|
CS-24VD-L1530
|
3-Phase, Delta 240V, 60Hz
|
20/30A
|
NEMA L1530
Cordset
|
(24) IEC 60320/C13
|
63.5"
1.75"
2.25"
|
|
CS-24VY-L2120
|
3-Phase, Delta 208V, 60Hz
|
20/30A
|
NEMA L21-20P
Cordset
|
(24) IEC 60320/C13
|
63.5"
1.75"
2.25"
|
|
CS-24VY-L2130
|
3-Phase, Delta 208V, 60Hz
|
20/30A
|
NEMA L21-30P
Cordset
|
(24) IEC 60320/C13
|
63.5"
1.75"
2.25"
|
|
|
| |
| IEC 60320/C19 to
L6-20P, 10'(PTCORD-1) |
PTCORD-1 |
| IEC 60320/C19 to
Schuko, 10'(PTCORD-2) |
PTCORD-2 |
| IEC 60320/C19 to
IEC 60309 (BS4343, CEE17) 16/20A Blue (PTCORD-3) |
PTCORD-3 |
| IEC 60320/C19 to
BS1363 13A (UK), 10'(PTCORD-4) |
PTCORD-4 |
| IEC60320/C19 to 5-15P
, 10'(PTCORD-5) |
PTCORD-5 |
| IEC60320/C19 to 5-20P,
10'(PTCORD-6) |
PTCORD-6 |
| IEC60320/C19 to L5-20P,
10'(PTCORD-7) |
PTCORD-7 |
| IEC 60320/C13 to
IEC 60320/C14, 7'(PTCORDPK-1) |
PTCORDPK-1 |
| IEC 60320/C13 to
IEC 60320/C14, 7'(PTCORD-PK-2) |
PTCORDPK-2 |
|
|
|