ServerTech CDU-24V Metered Power Distribution

ServerTech CDU-24V
ServerTech CDU-24V Smart Power Distribution
The ServerTech CDU-24V is a Smart CDU that delivers reliable
power distribution, local power monitoring via LEDs, power monitoring
via IP and enviornmental (temperature & humidity) monitoring
via IP.
Increasing power demands and density in the equipment cabinet
requires new functionality from your cabinet PDU. The Sentry
CDU product family uniquely meets these demands.
The Sentry Cabinet Power Distribution Unit (CDU) is an intelligent
PDU with local LED input current monitoring, allowing network
engineers to utilize the CDU’s True RMS Power Monitor to precisely
measure the current (in amps) that network devices are drawing
on the power circuit. As new equipment units are added to the
power drop, immediately observe its impact on the cumulative
current draw. This allows the engineer to safely load each circuit
to its maximum allowable load capacity without the danger of
overloading the power circuit.
The CDU meets new UL 60950-1 Branch Circuit Protection requirements.
Each branch circuit utilizes a Bussman® SC fuse as an Overcurrent
Protection Device (OCPD). Now you can safely run 30-amp power
drops to your server cabinet where individual outlet receptacles
have lower output ratings (i.e., 20-amps)
High Density 24-outlet power distribution with LED input
current display and branch circuit protection
ServerTech's CDU-24V Sentry CDU product family uniquely meets
these demands. ServerTech's CDU-24V Sentry Cabinet Power Distribution
Unit (CDU) is an intelligent PDU with local LED input current
monitoring, allowing network engineers to utilize the CDU’s
True RMS Power Monitor to precisely measure the current (in
amps) that network devices are drawing on the power circuit.
As new servers and devices are added to the power drop, immediately
observe its impact on the cumulative current draw. This allows
the engineer to safely load each circuit to its maximum allowable
load capacity without the danger of overloading the power circuit.
ServerTech CDU-24V Features:
- Branch Circuit Protection: The Sentry CDU Family
meets the new UL 60950-1 requirement for branch circuit
protection. Attention! The Sentry CDU products meet the
above criteria by providing overcurrent protection with
UL-listed Bussman SC fuses for each branch circuit.
- Branch Current Monitoring: The CDU’s exclusive
True RMS current monitoring is critical to preventing overloads
in high-density computing environments. LED digital displays
on the CDU enclosure report the input current of each phase
or branch circuit.
- Button Mounting: All CDUs are also compatible
with new button & “keyhole” style mounting for cabinets.
Several cabinet manufacturers are now using this method
for installing power distribution units in the cabinet.
- Cabinet Power Distribution: Reliable single &
three-phase power distribution for all the devices in your
equipment cabinet. Choose a single or dual-power feed model
to run all power cables to one side of the cabinet -- leaving
the other side open for data cable management
ServerTech CDU-24V Smart Power Distribution Specifications:
| |
|
CS-24V2-L630
|
208-240V
60Hz
|
20/30A
|
NEMA L6-30P
Cordset
|
(24) IEC 60320/C13
|
63.5”
1.75"
2.25”
|
|
CS-24VD-L1520
|
3-Phase, Delta 240V, 60Hz
|
20/30A
|
NEMA L1520
Cordset
|
(24) IEC 60320/C13
|
63.5”
1.75"
2.25”
|
|
CS-24VD-L1530
|
3-Phase, Delta 240V, 60Hz
|
20/30A
|
NEMA L1530
Cordset
|
(24) IEC 60320/C13
|
63.5”
1.75"
2.25”
|
|
CS-24VY-L2120
|
3-Phase, Delta 208V, 60Hz
|
20/30A
|
NEMA L21-20P
Cordset
|
(24) IEC 60320/C13
|
63.5”
1.75"
2.25”
|
|
CS-24VY-L2130
|
3-Phase, Delta 208V, 60Hz
|
20/30A
|
NEMA L21-30P
Cordset
|
(24) IEC 60320/C13
|
63.5”
1.75"
2.25”
|
|
|
| |
| IEC 60320/C19 to
L6-20P, 10' (PTCORD-1) |
PTCORD-1 |
| IEC 60320/C19 to
Schuko, 10' (PTCORD-2) |
PTCORD-2 |
| IEC 60320/C19 to
IEC 60309 (BS4343, CEE17) 16/20A Blue (PTCORD-3) |
PTCORD-3 |
| IEC 60320/C19 to
BS1363 13A (UK), 10' (PTCORD-4) |
PTCORD-4 |
| IEC60320/C19 to 5-15P
, 10' (PTCORD-5) |
PTCORD-5 |
| IEC60320/C19 to 5-20P,
10' (PTCORD-6) |
PTCORD-6 |
| IEC60320/C19 to L5-20P,
10' (PTCORD-7) |
PTCORD-7 |
| IEC 60320/C13 to
IEC 60320/C14, 7' (PTCORDPK-1) |
PTCORDPK-1 |
| IEC 60320/C13 to
IEC 60320/C14, 7' (PTCORD-PK-2) |
PTCORDPK-2 |
|
|
|