42U for Sentry Metered Power Solutions

Sentry PTPD-VL08
Sentry Metered Power Solutions

Sentry PTPD-VL08


Sentry PTPD-VL08

The Sentry PDU is a half-rack enclosure for power distribution of up to 30-Amps and is ideal for use in data-center, industrial and laboratory environments. This intelligent rack PDU power strip features an Input Current Monitor built-in to the enclosure to display the current load in amps on each power circuit. The Sentry PDU-VL08 features eight outlet receptacles and is available either as 110 or 208 VAC. An Audible alarm indicates an overload warning and two 15-amp circuit breakers provide overload protection.

  • 30-Amp power distribution

  • Qty 8 output receptacles

  • Half-rack form factor

  • Input Current monitor precisely measures and reports the current draw (in amps) that servers and network devices are drawing on the power circuit. A LED digital display indicator on the front panel of the Power Tower reports the current for on-site measurement.

  • Intelligent rack PDU power strip with LED amp display.

  • Qty 2 15-Amp circuit breaker protection

Sentry PTPD-VL08 Key Features and Benefits:

Sentry PTPD-VL08 True RMS Input Current Monitoring: Input Current Monitoring in Sentry power products is reported as the cumulative load (in amps) on each power circuit so that data center managers can obtain the data they need to plan their power requirements and to monitor power to their IT equipment. Input Current is reported in Amps and can be viewed locally on the enclosure via an LED Digital Display and remotely, when applicable, via the firmware interface.

Sentry PTPD-VL08 LED Digital Display Input Current Monitor: Easy viewing display on the face of the enclosure that reports the True RMS Power Monitoring of the aggregate load on the power circuit (in amps). The Input Current Display allows installation engineers to verify the real-time current draw on the power circuit. This eliminates the guesswork of estimating the current draw and prevents the costly mistake of: 1) overestimating and requiring extra power drops installed or 2) underestimating and overloading a circuit - putting the enter cabinet at risk if a circuit breaker at the main PDU trips.

Sentry PTPD-VL08 Zero U Enclosure: A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

Sentry PTPD-VL08 20-amp Power Input Support: 20-amp Power Input Support. IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX).

Sentry PTPD-VE18 30-Amp Power Input Support: 30-amp Power Input Support. Hard-wired with 10' cord and appropriate L5-30 or L6-30 plug type.

Sentry PTPD-VE18 Overcurrent Alarm: Audible (local) alarm sounds when defined maximum current load (amps) is exceeded.

Sentry PTPD-VL08 Specifications
Item # Description Maximum
Input/
Output
Maximum Output per Receptacle Receptacle Type Dimensions
PTPD-VL08-1 Sentry PDU, Vertical
8 Outlets
Circuit breakers @ 1-4 & 5-8
Input Current Display
Audible Overload Alarm
30-Amp
110 VAC
20-Amp 5-20R 33"H
2.25" D
1.75" W
includes mounting brackets
PTPD-VL08-2 Sentry PDU, Vertical
8 Outlets
Circuit breakers @ 1-4 & 5-8
Input Current Display
Audible Overload Alarm
30-Amp
208 VAC
20-Amp 5-20R 33"H
2.25" D
1.75" W
includes mounting brackets
 

ServerTech Sentry PTPD-VL08 Downloads & Manuals