42U for Sentry PTPD-V016 Solutions

Sentry PTPD-V016
Sentry PTPD Remote Reboot

Sentry PTPD-V016


Sentry PTPD-V016

Vertical Zero U PDU Power Strip

The Sentry Power Distribution Unit (PTPD) is an enhanced zero U solution, allowing Network engineers to utilize the PTPD's True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, one may immediately observe its impact on the cumulative current draw. Therefore, the engineer can safely load the Power distribution unit's circuit to its maximum allowable load capacity without the danger of overloading the power circuit. The Power Tower PDU also features current overload warning.

  • 15, 20, or 30-Amp power input feed with straight-blade or twist-lock connectors, 120V

  • Precisely measures and reports the current (in amps) that network devices are drawing on each power circuit. An LED digital display indicator on the front panel of the Power Tower reports the current for on-site measurement.

  • Configure the Power Tower Power Distribution Unit (PTPD) with a maximum input current rating to prevent an overload. An audible alarm signals with the Input Current Threshold has been exceeded and continues to sound until the Input Current drops below the threshold value.

Sentry PTPD-V016 Product Details:

Sentry PTPD-V016 True RMS Input Current Monitoring: Input Current Monitoring in Sentry power products is reported as the cumulative load (in amps) on each power circuit so that data center managers can obtain the data they need to plan their power requirements and to monitor power to their IT equipment. Input Current is reported in Amps and can be viewed locally on the enclosure via an LED Digital Display and remotely, when applicable, via the firmware interface.

Sentry PTPD-V016 LED Digital Display Input Current Monitor: Easy viewing display on the face of the enclosure that reports the True RMS Power Monitoring of the aggregate load on the power circuit (in amps). The Input Current Display allows installation engineers to verify the real-time current draw on the power circuit. This eliminates the guesswork of estimating the current draw and prevents the costly mistake of: 1) overestimating and requiring extra power drops installed or 2) underestimating and overloading a circuit - putting the enter cabinet at risk if a circuit breaker at the main PDU trips.

Sentry PTPD-V016 Zero U Enclosure: A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet

Sentry PTPD-V016 20-Amp Power Input Support: IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX).

Sentry PTPD-V016 30-Amp Power Input Support: Hard-wired with 10' cord and appropriate L5-30 or L6-30 plug type.

Sentry PTPD-V016 Over-current Alarm: Audible (local) alarm sounds when defined maximum current load (amps) is exceeded.

Sentry PTPD-V016 Specifications
Item # Description Maximum Input/Output Maximum Output Per Receptacle Receptacle
Type
Comms.
Interface
PTPD-V016-1-0x 16-Port Vertical 100-120V 30-Amp 10-Amp NEMA 5-20R Qty (16) RS-232 to set overload warning

Dimensions
66.00" (L) 1.75" (W) 2.25" (D)

Power Tower Input Connectors/Cables
0x (x=) Standard Connectors
1 100-120 V 5-20P Straight blade
2
(Discontinued)
20-Amp plug 208-240 VNO CABLE INCLUDED - Specify Cable at ordering
Optional Connectors
3 5-15P Straight Blade
15 Amp plug, 110 Vac
4 L5-20P Twist Lock
 20 Amp plug, 110 Vac
5
(Discontinued)
L5-30P Twist Lock
30 Amp plug, 110 Vac
0 Misc/Custom
Agency Approvals & Certifications

FCC - Class A
CE
CTUVus - CSA 22.2 No. 60950-00 3rd edition UL Std. 60950 3rd edition