Sentry PTPD-V008
Zero U 30-Amp Power Distribution
Unit
The Sentry Power Distribution Unit (PTPD) is an enhanced
zero U solution, allowing Network engineers to utilize
the PTPD's True RMS Power Monitor to precisely measure
the current (in amps) that network devices are drawing
on the power circuit. As new equipment units are added
to the power drop, one may immediately observe its impact
on the cumulative current draw. Therefore, the engineer
can safely load the Power distribution unit's circuit
to its maximum allowable load capacity without the danger
of overloading the power circuit. The Power Tower PDU
also features current overload warning.
-
15, 20, or 30-Amp power input feed with straight-blade
or twist-lock connectors, 120V
-
Precisely measures and reports the current (in amps)
that network devices are drawing on each power circuit.
An LED digital display indicator on the front panel
of the Power Tower reports the current for on-site
measurement.
-
Configure the Power Tower Power Distribution Unit
(PTPD) with a maximum input current rating to prevent
an overload. An audible alarm signals with the Input
Current Threshold has been exceeded and continues
to sound until the Input Current drops below the
threshold value.

Sentry PTPD-V008 Product Details:
Sentry PTPD-V008 True RMS Input Current
Monitoring: Input Current Monitoring in Sentry power
products is reported as the cumulative load (in amps)
on each power circuit so that data center managers can
obtain the data they need to plan their power requirements
and to monitor power to their IT equipment. Input Current
is reported in Amps and can be viewed locally on the
enclosure via an LED Digital Display and remotely, when
applicable, via the firmware interface.
Sentry PTPD-V008 LED Digital Display
Input Current Monitor: Easy viewing display on the
face of the enclosure that reports the True RMS Power
Monitoring of the aggregate load on the power circuit
(in amps). The Input Current Display allows installation
engineers to verify the real-time current draw on the
power circuit. This eliminates the guesswork of estimating
the current draw and prevents the costly mistake of:
1) overestimating and requiring extra power drops installed
or 2) underestimating and overloading a circuit - putting
the enter cabinet at risk if a circuit breaker at the
main PDU trips.
Sentry PTPD-V008 20-Amp Power Input
Support: IEC320/C20 power inlet receptacles supports
any power cord with IEC320/C19 power connector (PTCORD-XX).
Sentry PTPD-V008 30-Amp Power Input
Support: Hard-wired with 10' cord and appropriate
L5-30 or L6-30 plug type.
Sentry PTPD-V008 Over-current Alarm:
Audible (local) alarm sounds when defined maximum current
load (amps) is exceeded.
|
Sentry PTPD-V008
Specifications |
|
Item
# |
Description |
Maximum Input/Output
|
Maximum Output
Per Receptacle |
Receptacle
Type |
Comms.
Interface |
|
PTPD-V008-1-0x |
8-Port Vertical
100-120V |
30-Amp |
10-Amp |
NEMA 5-20R
Qty (8) |
RS-232 to
set overload warning |
|
Dimensions
43.25" (L) 1.75" (W) 2.25" (D)
|
|
Power Tower Input
Connectors/Cables |
|
0x |
(x=) Standard Connectors |
|
1 |
100-120 V
5-20P Straight blade |
2
(Discontinued) |
20-Amp plug
208-240 VNO CABLE INCLUDED - Specify Cable
at ordering |
|
Optional Connectors
|
|
3 |
5-15P Straight
Blade
15 Amp plug, 110 Vac |
|
4 |
L5-20P Twist
Lock
20 Amp plug, 110 Vac |
5
(Discontinued) |
L5-30P Twist
Lock
30 Amp plug, 110 Vac |
|
0 |
Misc/Custom |
|
Agency Approvals
& Certifications |
|
FCC - Class
A
CE
CTUVus - CSA 22.2 No. 60950-00 3rd edition
UL Std. 60950 3rd edition
|
ServerTech Sentry PTPD-V008 Downloads & Manuals