42U for Sentry Metered Power Solutions

Sentry PTPD-H016
Sentry Metered Power Solutions

ServerTech Rack PDU's
PTPD-H016

 
 
Green Data Center
Green Data Center

42U Partial Client List
15-Years of Customer Astonishment!

Webinar Replay: Hot Aisle / Cold Aisle Containment
Hot Aisle / Cold Aisle Thermal Containment
Data Center Energy Efficiency Savings Calculator
Efficiency Savings Calculator

PUE Calculator / DCiE Calculator
PUE / DCiE Calculator

Data Center Efficiency Best Practices
Efficiency Best Practices

    
Request Price Quote
 Request Quote

Request Quote

Free Project Consultation
 Free Project Consultation

Free Project
Consultation

Free Product Evaluation
 Free Product Evaluation

Free 30-Day
Product Eval

Data Center Energy Efficiency Savings Calculator
 Energy Efficiency Savings Calculator

Efficiency Savings Calculator

    

Sentry PTPD-H016

ServerTech Sentry PTPD-H016
Sentry PTPD-H016
30-Amp Power Distribution with a True RMS Power Monitor

The Sentry Power Distribution Unit (PTPD) is an enhanced zero U or rack-mount solution, allowing Network engineers to utilize the PTPD's True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new equipment units are added to the power drop, one may immediately observe its impact on the cumulative current draw. Therefore, the engineer can safely load the circuit to its maximum allowable load capacity without the danger of overloading the power circuit. The Power Tower PDU also features current overload warning.

  • 15, 20, or 30-Amp power input feed with straight-blade or twist-lock connectors. 120V or 230V

  • Precisely measures and reports the current (in amps) that network devices are drawing on each power circuit with the True RMS power monitor. An LED digital display indicator on the front panel of the Power Tower reports the current for on-site measurement.

  • Configure the Power Tower Power Distribution Unit (PTPD) with a maximum input current rating to prevent an overload. An audible alarm signals with the Input Current Threshold has been exceeded and continues to sound until the Input Current drops below the threshold value.

Sentry PTPD-H016 Key Features and Benefits:

Sentry PTPD-H016 True RMS Input Current Monitoring: Input Current Monitoring in Sentry power products is reported as the cumulative load (in amps) on each power circuit so that data center managers can obtain the data they need to plan their power requirements and to monitor power to their IT equipment. Input Current is reported in Amps and can be viewed locally on the enclosure via an LED Digital Display and remotely, when applicable, via the firmware interface.

Sentry PTPD-H016 Rack-Mount Enclosure: 1U and 2U "horizontal" rack-mount enclosures are 17" wide and include standard mounting brackets for 19" cabinet rails. 23" brackets also available.

Sentry PTPD-H016 LED Digital Display Input Current Monitor: Easy viewing display on the face of the enclosure that reports the True RMS Power Monitoring of the aggregate load on the power circuit (in amps). The Input Current Display allows installation engineers to verify the real-time current draw on the power circuit. This eliminates the guesswork of estimating the current draw and prevents the costly mistake of: 1) overestimating and requiring extra power drops installed or 2) underestimating and overloading a circuit - putting the enter cabinet at risk if a circuit breaker at the main PDU trips.

Sentry PTPD-H016 20-amp Power Input Support: 20-amp Power Input Support. IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX).

Sentry PTPD-H016 30-Amp Power Input Support: 30-amp Power Input Support. Hard-wired with 10'cord and appropriate L5-30 or L6-30 plug type.

Sentry PTPD-H016 Overcurrent Alarm: Audible (local) alarm sounds when defined maximum current load (amps) is exceeded.

Sentry Power Tower PDU Specifications
Item # Description Maximum Input/Output Maximum Output Per Receptacle Receptacle Type Dimensions Comm. Interface
PTPD-H016-1-0x 16-Port Horizontal
100-120V
30A 10A NEMA 5-20R
Qty (16)
3.5" (L)
17" (W)
8" (D)
RS-232 to set overload warning
PTPD-H016-2-02 16-Port Horizontal
208-240V
30A (US/CSA)
16A Intl.
8A IEC C13
Qty (16)
3.5" (L)
17" (W)
2.25" (D)
RS-232 to set overload warning
Sentry Power Tower Input Connectors/Cables
0x (x=) Standard Connectors
1 100-120 V 5-20P Straight blade
2 20-Amp plug 208-240 VNO CABLE INCLUDED -- Specify Cable at ordering
Optional Connectors  
3 5-15P Straight Blade 15 Amp plug, 110 Vac
4 L5-20P Twist Lock 20 Amp plug, 110 Vac
5 L5-30P Twist Lock 30 Amp plug, 110 Vac
6 L6-30P Twist Lock 30-amp plug, 230 Vac
0 Misc/Custom
208-240 V Optional Connectors  
PTCORD-1 IEC 60320/C19 - L6-20P, 10'
PTCORD-2 IEC 60320/C19 - Schuko, 10'
PT-ADP-C19 Cable mount IEC 60320/C19 Connector
Agency Approvals & Certifications
FCC Class A
CE  
CTUVus CSA 22.2 No. 60950-00 3rd edition UL Std. 60950 3rd edition
TUVGS EN 60950 3rd edition
 

ServerTech Sentry PTPD-H016 Downloads & Manuals

 Home About 42U Careers Clients Vendors Press Articles Efficiency Glossary Site Map Efficiency Calculator
Data Center Solutions UPS Power Data Center Efficiency Efficiency Services Rack Accessories Efficiency Best Practices Lights Out
Follow us on:
 Follow 42u on Twitter Subscribe to 42U's channel on YouTube View 42u's profile on slideshare

Sentry PTPD-H016