Sentry PTPD-H008
30-Amp Power Distribution with a True RMS Power Monitor
The Sentry Power Distribution Unit (PTPD) is
an enhanced rack-mount solution, allowing Network engineers
to utilize the PTPD's True RMS Power Monitor to precisely measure
the current (in amps) that network devices are drawing on the
power circuit. As new equipment units are added to the power
drop, one may immediately observe its impact on the cumulative
current draw. Therefore, the engineer can safely load the circuit
to its maximum allowable load capacity without the danger of
overloading the power circuit. The Power Tower PDU also features
current overload warning.
-
15, 20, or 30-Amp power input feed with
straight-blade or twist-lock connectors. 120V or 230V
-
Precisely measures and reports the current
(in amps) that network devices are drawing on each power
circuit with the True RMS power monitor. An LED digital
display indicator on the front panel of the Power Tower
reports the current for on-site measurement.
-
Configure the Power Tower Power Distribution
Unit (PTPD) with a maximum input current rating to prevent
an overload. An audible alarm signals with the Input Current
Threshold has been exceeded and continues to sound until
the Input Current drops below the threshold value.

Sentry PTPD-H008 Key Features and Benefits:
Sentry PTPD-H008 True RMS Input Current Monitoring:
Input Current Monitoring in Sentry power products is reported
as the cumulative load (in amps) on each power circuit so that
data center managers can obtain the data they need to plan their
power requirements and to monitor power to their IT equipment.
Input Current is reported in Amps and can be viewed locally
on the enclosure via an LED Digital Display and remotely, when
applicable, via the firmware interface.
Sentry PTPD-H008 Rack-Mount Enclosure:
1U and 2U "horizontal" rack-mount enclosures are 17" wide and
include standard mounting brackets for 19" cabinet rails. 23"
brackets also available.
Sentry PTPD-H008 LED Digital Display Input
Current Monitor: Easy viewing display on the face of the
enclosure that reports the True RMS Power Monitoring of the
aggregate load on the power circuit (in amps). The Input Current
Display allows installation engineers to verify the real-time
current draw on the power circuit. This eliminates the guesswork
of estimating the current draw and prevents the costly mistake
of: 1) overestimating and requiring extra power drops installed
or 2) underestimating and overloading a circuit - putting the
enter cabinet at risk if a circuit breaker at the main PDU trips.
Sentry PTPD-H008 20-amp Power Input Support:
20-amp Power Input Support. IEC320/C20 power inlet receptacles
supports any power cord with IEC320/C19 power connector (PTCORD-XX).
Sentry PTPD-H008 30-Amp Power Input Support:
30-amp Power Input Support. Hard-wired with 10' cord and appropriate
L5-30 or L6-30 plug type.
Sentry PTPD-H008 Overcurrent Alarm: Audible
(local) alarm sounds when defined maximum current load (amps)
is exceeded.
|
Sentry Power Tower PDU
Specifications |
|
Item # |
Description |
Maximum Input/Output |
Maximum Output
Per Receptacle |
Receptacle Type |
Dimensions |
Comm. Interface |
|
PTPD-H008-1-0x |
8-Port Horizontal
100-120V |
30A |
10A |
NEMA 5-20R
Qty (8) |
1.75" (L)
17" (W)
8" (D) |
RS-232 to set overload
warning |
|
PTPD-H008-2-02 |
8-Port Horizontal
208-240V |
30A (US/CSA)
16A Intl. |
8A |
IEC C13
Qty (8) |
1.75" (L)
17" (W)
2.25" (D) |
RS-232 to set overload
warning |
|
Sentry Power Tower
Input Connectors/Cables |
|
0x |
(x=) Standard Connectors |
|
1 |
100-120 V 5-20P Straight
blade |
|
2 |
20-Amp plug 208-240
VNO CABLE INCLUDED -- Specify Cable at ordering
|
|
Optional Connectors |
|
|
3 |
5-15P Straight Blade
15 Amp plug, 110 Vac |
|
4 |
L5-20P Twist Lock
20 Amp plug, 110 Vac |
|
5 |
L5-30P Twist Lock
30 Amp plug, 110 Vac |
|
6 |
L6-30P Twist Lock
30-amp plug, 230 Vac |
|
0 |
Misc/Custom |
|
208-240 V Optional Connectors
|
|
|
PTCORD-1 |
IEC 60320/C19 - L6-20P,
10' |
|
PTCORD-2 |
IEC 60320/C19 - Schuko,
10' |
|
PT-ADP-C19
|
Cable mount IEC 60320/C19
Connector |
|
Agency Approvals & Certifications |
|
FCC |
Class A |
|
CE |
|
|
CTUVus |
CSA 22.2 No. 60950-00
3rd edition UL Std. 60950 3rd edition |
|
TUVGS |
EN 60950 3rd edition |
ServerTech Sentry PTPD-H008 Downloads & Manuals