42U for Sentry CDU-24V-3Ph Solutions

Sentry CDU-24V-3Ph
Sentry CDU Remote Reboot

ServerTech Rack PDU's
CDU-24V-3PH

 
 
Green Data Center
Green Data Center

42U Partial Client List
15-Years of Customer Astonishment!

Webinar Replay: Hot Aisle / Cold Aisle Containment
Hot Aisle / Cold Aisle Thermal Containment
Data Center Energy Efficiency Savings Calculator
Efficiency Savings Calculator

PUE Calculator / DCiE Calculator
PUE / DCiE Calculator

Data Center Efficiency Best Practices
Efficiency Best Practices

    
Request Price Quote
 Request Quote

Request Quote

Free Project Consultation
 Free Project Consultation

Free Project
Consultation

Free Product Evaluation
 Free Product Evaluation

Free 30-Day
Product Eval

Data Center Energy Efficiency Savings Calculator
 Energy Efficiency Savings Calculator

Efficiency Savings Calculator

    

Sentry CDU-24V-3Ph

Sentry CDU-24V-3Ph
Sentry CDU-24V-3Ph

Three-phase Switched Power Control via IP, 24 outlets with LED input current displays, branch circuit protection and IP monitoring ; high-density.

The Sentry CDU combines remote configuration and management with power distribution, power monitoring and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.

Only the Sentry CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current monitoring.

The Sentry CDU also supports Enterprise View PDU Manager. This gives the engineer the ability to manage a large installation of Networked CDUs from one location, view and access up to 1,000 Switched CDUs from a single web interface.

Sentry CDU-24V-3Ph Product Details:

Sentry CDU-24V-3Ph SSL Web Browser: Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers. Sentry supports SSLv3/TLSv1.

Sentry CDU-24V-3Ph HTTP/HTTPs Web Configuration & Control: Use the Sentry Web interface to configure each unit, including network settings, outlet naming & grouping, SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to control individual or group outlets and monitor environmental conditions. SSL security provides a secure HTTPs connection.

Sentry CDU-24V-3Ph Remote Outlet Grouping & Control: Assign outlets to a group for control of dual-power supply servers and other gear with a single command. Create an unlimited number of groups with any combination of outlets associated to each group.

Sentry CDU-24V-3Ph SSH Management: Secure Shell (SSH), sometimes known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device. Sentry supports SSHv2.

Sentry CDU-24V-3Ph SNMP Management: The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information and control power for the individual outlets. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control.

Sentry CDU-24V-3Ph LDAP: LDAP (Lightweight Directory Access Protocol) is a software protocol for enabling anyone to locate organizations, individuals, and other resources such as files and devices in a network, whether on the public Internet or on a corporate intranet.
Sentry firmware code 5.3b and newer includes support for LDAP v3 and is configurable to operate with any Directory Service. It has been tested with these Directory Services:

  • Microsoft's Active Directory
  • Novell's eDirectory
  • OpenLDAP

Sentry CDU-24V-3Ph RS-232 Control: Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.

Sentry CDU-24V-3Ph Telnet Management: Telnet is a user command and an underlying TCP/IP protocol for accessing remote computers.

Sentry CDU-24V-3Ph SNMP Traps for Event Notification: SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, closed contacts (cabinet doors open/close), as well as notification of any time an outlet status is changed (on/off).

Sentry CDU-24V-3Ph Power-Up Sequencing: Prevent a power in-rush from overloading the power circuit. In the event of a power loss, this key feature prevents all power-outlet receptacles from powering on at once - averting the potential for a power in-rush to blow a fuse or circuit breaker in the data center. Instead, the power-outlet receptacles power-on in two-second intervals, allowing each device to safely boot-up. Power-up sequencing is a default hardware setting. User adjustable.

Sentry CDU-24V-3Ph True RMS Input Current Monitoring: Input Current Monitoring in Sentry power products is reported as the cumulative load (in amps) on each power circuit so that data center managers can obtain the data they need to plan their power requirements and to monitor power to their IT equipment. Input Current is reported in Amps and can be viewed locally on the enclosure via an LED Digital Display and remotely, when applicable, via the firmware interface.

Sentry CDU-24V-3Ph High-amp In-rush Protection: High-Amp In-rush relays accommodate the extremely high power in-rush spikes from today's switching power supplies.

Sentry CDU-24V-3Ph Multiple Concurrent Users: Multiple concurrent users allows several users to be logged into a Sentry at the same time. In this way, different users, with access rights to only their equipment, can reboot their device(s) when they need to, without waiting for another user to log out of the Sentry unit.

Sentry CDU-24V-3Ph 24-character Outlet Receptacles Names: Use the firmware interface (Web or serial) to edit individual outlet receptacles. Identify each receptacle with the device's serial number, IP address, asset allocation #, department or any other method to individually name outlets.

Sentry CDU-24V-3Ph 20-Amp Power Input Support: 20-amp Power Input Support. IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX).

Sentry CDU-24V-3Ph 30-Amp Power Input Support: 30-amp Power Input Support. Hard-wired with 10'cord and appropriate L5-30 or L6-30 plug type.

Sentry CDU-24V-3Ph Zero U Enclosure: A vertical enclosure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavity space of the cabinet.

Sentry CDU-24V-3Ph LED Digital Display Input Current Monitor: Easy viewing display on the face of the enclosure that reports the True RMS Power Monitoring of the aggregate load on the power circuit (in amps). The Input Current Display allows installation engineers to verify the real-time current draw on the power circuit. This eliminates the guesswork of estimating the current draw and prevents the costly mistake of: 1) overestimating and requiring extra power drops installed or 2) underestimating and overloading a circuit - putting the enter cabinet at risk if a circuit breaker at the main PDU trips.

Sentry CDU-24V-3Ph Integrate Environmental Monitoring: The EMCU integrates easily with the Power Tower XL, or other Sentry Remote Power Manager. Locate the EMCU in an equipment cabinet with a PTXL, link it to the PTXL and view temperature, humidity, water sensing and dry contact closures from the same PTXL interface you use to manage & monitor the power.

Sentry CDU-24V-3Ph Authentication:   16-character Username & Password required for network administrators & user accounts. Multiple user accounts can be established with access rights only to designated outlets.

Sentry CDU-24V-3Ph Branch Circuit Protection: Sentry PDUs are safety-agency certified to the new UL 60950-1 standard (CSA/UL/TUV) & the National Electrical Code (NEC), which require branch circuit protection for receptacles.

Sentry CDU-24V-3Ph Firmware Flash Upgradeable: Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.

Sentry CDU-24V-3Ph Remote Individual Outlet control:  Reduce Mean Time to Repair (MTTR) of a failing server by controlling individual power outlet receptacles to reboot any selected server or other device.

Sentry CDU-24V-3Ph Always-On Outlets:  Outlets are powered-on in their default state. User action is required to perform a power-off or reboot to change the status of each power outlet receptacle's relay.

Sentry CDU-24V-3Ph Integrated Temp/Humidity Probes: Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with six-foot (6') cables provide real-time measurements in the data center cabinet.

Sentry CDU-24V-3Ph HTTP/HTTPs Web Monitoring:  Use the Web interface to access and monitor key values, including amperage load(s), temperature/humidity and other environmental factors.

Sentry CDU-24V-3Ph Fuse-protected outlets:  Power Outlet protection provided by fuses.

Sentry CDU-24V-3Ph EV-200:  Enterprise View 200 auto discovers up to 200 Sentry devices.

Sentry CDU-24V-3Ph EV-1K:  Enterprise View 1K auto discovers up to 1,000 Sentry Devices

Sentry CDU-24V-3Ph Remote Power Control:  Individual or group outlet remote power control to cycle power and reboot any selected server(s) or other network device(s). Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with each Sentry and rectify locked-up network devices.

 
Item # Available Input
Voltages
Rated Amperage Available Input Cord Outlets Dimensions
CW-24VY-L2120 3-Phase 208V
60Hz
20/30A NEMA L21-20P
Cordset
(24) IEC 60320/C13 69.0"L, 1.75"W,
 2.25"D
CW-24VY-L2130 3-Phase 208V
60Hz
20/30A NEMA L21-30P
Cordset
(24) IEC 60320/C13 69.0"L, 1.75"W,
 2.25"D
 
 
ServerTech Power Cord Options Part Number
IEC 60320/C19 to L6-20P, 10'(PTCORD-1) PTCORD-1
IEC 60320/C19 to Schuko, 10'(PTCORD-2) PTCORD-2
IEC 60320/C19 to IEC 60309 (BS4343, CEE17) 16/20A Blue (PTCORD-3) PTCORD-3
IEC 60320/C19 to BS1363 13A (UK), 10'(PTCORD-4) PTCORD-4
IEC60320/C19 to 5-15P , 10'(PTCORD-5) PTCORD-5
IEC60320/C19 to 5-20P, 10'(PTCORD-6) PTCORD-6
IEC60320/C19 to L5-20P, 10'(PTCORD-7) PTCORD-7
IEC 60320/C13 to IEC 60320/C14, 7'(PTCORDPK-1) PTCORDPK-1
IEC 60320/C13 to IEC 60320/C14, 7'(PTCORD-PK-2) PTCORDPK-2
 
 
ServerTech Sentry CDU-24V-3Ph Downloads & Manuals
 
 Home About 42U Careers Clients Vendors Press Articles Efficiency Glossary Site Map Efficiency Calculator
Data Center Solutions UPS Power Data Center Efficiency Efficiency Services Rack Accessories Efficiency Best Practices Lights Out
Follow us on:
 Follow 42u on Twitter Subscribe to 42U's channel on YouTube View 42u's profile on slideshare

Sentry CDU-24V-3Ph