Sentry CDU-1806V2
ServerTech CDU-1806V2 Metered Power Distribution
ServerTech CDU-1806V2 Metered Power Distribution
12-outlet power distribution with LED input current display
and branch circuit protection.
Server Technology's CDU-1806V2 Sentry CDU product family
uniquely meets these demands. Server Technology's CDU-1806V2
Sentry Cabinet Power Distribution Unit (CDU) is an intelligent
PDU with local LED input current monitoring, allowing network
engineers to utilize the CDU’s True RMS Power Monitor to precisely
measure the current (in amps) that network devices aredrawing
on the power circuit. As new servers and devices are added to
the power drop, immediately observe its impact on the cumulative
current draw. This allows the engineer to safely load each circuit
to its maximum allowable load capacity without the danger of
overloading the power circuit.
ServerTech CDU-1806V2 Features:
- Branch Circuit Protection: The Sentry CDU Family
meets the new UL 60950-1 requirement for branch circuit
protection. Attention! The Sentry CDU products meet the
above criteria by providing overcurrent protection with
UL-listed Bussman SC fuses for each branch circuit.
- Branch Current Monitoring: The CDU’s exclusive
True RMS current monitoring is critical to preventing overloads
in high-density computing environments. LED digital displays
on the CDU enclosure report the input current of each phase
or branch circuit.
- Button Mounting: All CDUs are also compatible
with new button & “keyhole” style mounting for cabinets.
Several cabinet manufacturers are now using this method
for installing power distribution units in the cabinet.
- Cabinet Power Distribution: Reliable single &
three-phase power distribution for all the devices in your
equipment cabinet. Choose a single or dual-power feed model
to run all power cables to one side of the cabinet -- leaving
the other side open for data cable management
ServerTech CDU-1806V2 Metered Power Distribution
Specifications:
| |
| IEC 60320/C19 to
L6-20P, 10' (PTCORD-1) |
PTCORD-1 |
| IEC 60320/C19 to
Schuko, 10' (PTCORD-2) |
PTCORD-2 |
| IEC 60320/C19 to
IEC 60309 (BS4343, CEE17) 16/20A Blue (PTCORD-3) |
PTCORD-3 |
| IEC 60320/C19 to
BS1363 13A (UK), 10' (PTCORD-4) |
PTCORD-4 |
| IEC60320/C19 to 5-15P
, 10' (PTCORD-5) |
PTCORD-5 |
| IEC60320/C19 to 5-20P,
10' (PTCORD-6) |
PTCORD-6 |
| IEC60320/C19 to L5-20P,
10' (PTCORD-7) |
PTCORD-7 |
| IEC 60320/C13 to
IEC 60320/C14, 7' (PTCORDPK-1) |
PTCORDPK-1 |
| IEC 60320/C13 to
IEC 60320/C14, 7' (PTCORD-PK-2) |
PTCORDPK-2 |
|
|
|