| |  Powerware 9140 UPS series
The Powerware 9140 uninterruptible power system (UPS) delivers de-centralized power protection and power management for medium- and high-density rack environments and superior power management for expanding loads in shrinking spaces. Providing increased power density and power protection capabilities, the 9140 rackmount UPS delivers efficient, reliable power protection in only 6U of rack space, including batteries. This double-conversion, online rackmount UPS resolves all nine common utility power problems and supplies clean, continuous power to all connected equipment. If utility power goes out altogether, there is no delay transferring to backup power, either to UPS batteries or an auxiliary generator. Powerware 9140 UPS Features and Benefits: Protects mission-critical rackmount applications from downtime, data loss /corruption, and process interruption by providing continuous, clean power with double-conversion, online topology Conserves valuable rack space with up to 10 kVA of power in only 6U of height, including batteries Pre-installed rackmount hardware significantly reduces installation time Modular, lightweight design facilitates installation and improves service time Upgradeable from 7.5 kVA to 10 kVA, to accommodate system growth ABM technology significantly increases battery life, resulting in more uptime and fewer battery replacements Lightweight hot-swappable battery and electronics modules allow for easy installation and service Extends battery runtime for up to 45 minutes with up to four 3U EBMs Intuitive LCD interface provides detailed information and UPS management in multiple languages USB and serial ports standard, optional X-slot communication card Backed by two-year limited warranty, 10-year pro-rated warranty and $250,000 load protection guarantee
Powerware 9140 UPS Technical Specifications | Electrical Input | | | | | Nominal input voltage | Single-phase | | 200-208V (for 200-208V nominal output); 220-240V | | Three-phase | | 380/220V, 400/230V, 415/240V | | Input voltage range | Single-phase | | 160-253V (for 200-208V nominal output); 174-288V (for 220-240V nominal output) | | Three-phase | | 301-499V / 174-288V | | Operating frequency | | | 45-55 Hz range for 50 Hz nominal; 55-65 Hz range for 60 Hz nominal | | Input power factor | | | PF > 0.99 | | Input current distortion | | | <5% THD | | Electrical Output | | | | | Single-phase | | | 200V / 208V / 220V / 230V / 240V user-selectable | | Output voltage regulation | | | +/- 2% static, +/- 10% dynamic | | Efficiency | | | >90% | | Output Frequency | | | Automatic selection of 50 Hz nominal (+/- 3.5 Hz) and 60 Hz nominal (+/- 3.5Hz) | | Battery Type | | | 12V, 5 Ah, sealed, lead-acid, maintenance-free | | Battery Replacement | | | Modular, hot-swappable, user-replaceable | | Charger | | | 2.5A charger to support up to 4 additional EBMs | | Start-On-Battery | | | Allows startup of UPS without utility input | | Communications | | | | | LCD Display | | | Multilingual Graphical LCD with backlight | | LEDs | | | (4) LEDs for notice and alarm | | Communication Ports | | | (1) USB, (1) RS-232 serial, (1) REPO | | Communication Slot | | | (1) X-Slot communication bay | | Power Management Software | | | Bundled software suite CD Powerware 9140 is HID-compliant | | General | | | | | Dimensions | | | HxWxD, in / mm | | | PW9140 UPS | | 10.5 (6U) x 17 x 30.0 / 263 x 430 x 760 | | | PW9140 EBM | | 5.25 (3U) x 17 x 26 / 131 x 430 x 660 | | Weight | PW9140 UPS | | 254 lb | | | PW9140 EBM | | 175 lb | | Battery Module | | | 37 lbs | | Power Module | | | 40 lbs | | UPS Bypass | | | Automatic on overload, overtemp, UPS failure, or removal of power module | | Overload to bypass | | | +/- 10% of 112 to 130% for 60 seconds, transfer | | Environmental | RoHS Compliance | | EU RoHS / WEEE Compliant | | | Operating Temperature | | 0°C to 40°C (32°F to 104°F) | | | Transit and Storage Temperature | | -20°C to +50°C (-4°F to 122°F) | | | Relative Humidity | | 0-95% non-condensing | | | Altitude | | Operating 3000m, Transit 15000m | | | Audible Noise | | <55 dBA at 5 feet | | Certifications | Safety Certifications | | UL, cULus, NOM, TUV, CE | | | EMC Compliance Markings | | FCC, CE, VCCI, C-tick |
Powerware 9140 UPS Models
| Model | Part Number | Input Connection | Input/Output Voltages | Power Rating | Run times half/full load (mins) | Price | | PW 9140 7500 | 103005094-6591 | (1) IEC-309 | 208, 220, 230, 240 VAC/208, 220, 230, 240 VAC | 7500 | 18 / 7 | $5,919 | | PW 9140 7500 HW | 103005093-6591 | (1) Hardwired | 208, 220, 230, 240 VAC/208, 220, 230, 240 VAC | 7500 | 18 / 7 | $5,394 | | PW 9140 10000 | 103004727-6591 | (1) IEC-309 | 208, 220, 230, 240 VAC/208, 220, 230, 240 VAC | 10000 | 12 / 5 | $6,779 | | PW 9140 10000HW | 103004728-6591 | (1) Hardwired | 208, 220, 230, 240 VAC/208, 220, 230, 240 VAC | 10000 | 12 / 5 | $6,344 |
| | | | | | Powerware Three-Phase UPS System | | | | | Eaton Powerware UPS Appliance | Power Range | Topology | | Powerware BladeUPS Powerware BladeUPS System expands power protection from 12 kW to 60 kW in a single industry-standard 19" rack. | 180 to 265 Vac, 311 to 519 Vac | Online, Double-conversion on Demand |  |
| | | | | |
| |