 Powerware 9120 UPS series
The Powerware 9120 UPS provides maximum power quality and backup power protection in the 700 - 3000 VA range and is the ideal power management solution for networks, Web servers and telecommunications equipment. While offering basic surge protection and backup power, the Powerware 9120 UPS additionally offers the best UPS power protection against all nine common power quality problems. Powerware 9120 UPS Features and Benefits: Powerware 9120 UPS Technical Specifications: | Electrical Input | Nominal Voltage | | 120 Vac and 230 Vac; | | Input Voltage Range | | 120V: 80 -144 Vac 230V: 120/140/160-276 Vac | | Input Power Factor | | >.95% | | Operating Frequency | | 50/60 Hz, Auto-sensing | | Frequency Range | | 45 - 65 Hz | | Input Protection | | Fuse or circuit breaker | | Electrical Output | On Utility Voltage Regulation | | +/-2% of nominal | | On Battery Voltage Regulation | | +/-3% of nominal | | Nominal Output Voltage | | Same as selected input voltage | | Output Voltage Waveform | | Sine Wave | | Output Voltage Distortion | | <3%THD | | Output protection | | Electronic overload sensing, and circuit breaker protection | | Efficiency | | Online Mode:>86%; Hi-Efficiency Mode:>90% | | Battery | Internal Battery type | | Sealed, lead-acid; maintenance free | | | EBM Battery Type | | Sealed, lead-acid; maintenance free | | | Battery Replacement | | Hot-swappable internal and external batteries | | | Recharge Time | | <4 hours to 90%capacity | | | Start-On-Battery | | Allows start of UPS without utility input | | Communications | User Interface | | LCD status screen | | | Audible Alarms | | UPS alarm conditions, including: On-Battery, Low Battery, Overload, UPS Fault | | | Network transient Protector | | In and out jack for all models. UL497A tested | | | REPO Port | | Meets NEC code 645-11 intent and UL requirements | | | Communications | | One RS232 Serial Port; One Communications Slot; One USB Port | | | Communications cable | | 6-foot communications cable included | | General | Topology | | True online, double-conversion | | | Diagnostics | | Full system self-test on power up | | | UPS Bypass | | Automatic on Overload or UPS failure <4ms | | | Transfer Time to battery | | 0 ms | | | Overload Capacity | | 125% for 10 minutes before transfer to bypass; 150% for 10 seconds before transfer to bypass | | Environmental and Safety | Safety Certifications | | UL1778;cUL22.2 NO.107. | | | EMI Compliance | | FCC Part 15, Class B (700-1500), Class A (2000-3000) 230 V, EN 50091-2 Class B (700-1500), Class A (2000-3000) | | | Operating Temperature | | 0 to 40 C (32 to 104 F) | | | Storage Temperature | | -15 to 50 C (5 to 122 F) | | | Relative Humidity | | 0%to 95%non-condensing | | | Immunity | | EEE C62.41, IEC 61000-4 -2, -3, -4, -5 | | | Network Transient Protector | | UL497A | | | Audible Noise at 1 meter | | 700-1000 VA: <45dB;1500 VA <50dB; 2000-3000 <52dB | | | Altitude | | 3000m (10,000 ft) without deteriorating |
Powerware 9120 UPS Models
| Model | Part Number | Input Connection | Input/Output Voltages | Power Rating | Run times half/full load (mins) | Price | | PW 9120 700 | 05147356-5591 | (1) NEMA 5-15P | 120VAC/120VAC | 700 | 23 / 7 | $760 | PW 9120 700 with 1 EBM | 05147356-5591 05147366-5592 | (1) NEMA 5-15P | 120VAC/120VAC | 700 | 75 / 35 | $1,240 | PW 9120 700 with 2 EBMs | 05147356-5591 05147366-5592 | (1) NEMA 5-15P | 120VAC/120VAC | 700 | 145 / 65 | $1,720 | | PW 9120 1000 | 05147357-5591 | (1) NEMA 5-15P | 120VAC/120VAC | 1000 | 21 / 7 | $900 | | PW 9120 1500 | 05147358-5591 | (1) NEMA 5-15P | 120VAC/120VAC | 1500 | 20 / 7 | $1,280 | PW 9120 1500 with 1 EBM | 05147358-5591 05147368-5592 | (1) NEMA 5-15P | 120VAC/120VAC | 1500 | 80 / 33 | $1,960 | PW 9120 1500 with 2 EBMs | 05147358-5591 05147368-5592 | (1) NEMA 5-15P | 120VAC/120VAC | 1500 | 150 / 60 | $2,640 | | PW 9120 2000 | 05147359-5591 | (1) NEMA 5-20P | 120VAC/120VAC | 2000 | 30 / 14 | $1,720 | PW 9120 2000 with 1 EBM | 05147359-5591 05147369-5592 | (1) NEMA 5-20P | 120VAC/120VAC | 2000 | 125 / 55 | $2,700 | PW 9120 2000 with 2 EBMs | 05147359-5591 05147369-5592 | (1) NEMA 5-20P | 120VAC/120VAC | 2000 | 220 / 100 | $3,680 | | PW 9120 3000 | 05147360-5591 | (1) NEMA L5-30P | 120VAC/120VAC | 3000 | 19 / 8 | $2,680 | PW 9120 3000 with 1 EBM | 05147360-5591 05147369-5592 | (1) NEMA L5-30P | 120VAC/120VAC | 3000 | 70 / 30 | $3,660 | PW 9120 3000 with 2 EBMs | 05147360-5591 05147369-5592 | (1) NEMA L5-30P | 120VAC/120VAC | 3000 | 140 / 65 | $4,640 | | PW 9120 3000B | 05147548-5591 | (1) NEMA L6-20P | 208VAC/208VAC | 3000 | 19 / 9 | $2,680 | | PW 9120 3000H | 05147547-5591 | (1) Hardwired | 120VAC/120VAC | 3000 | 19 / 8 | $2,680 | PW 9120 3000H with 1 EBM | 05147547-5591 05147369-5592 | (1) Hardwired | 120VAC/120VAC | 3000 | 70 / 30 | $3,660 | PW 9120 3000H with 2 EBMs | 05147547-5591 05147369-5592 | (1) Hardwired | 120VAC/120VAC | 3000 | 140 / 65 | $4,640 |
Click here to download the Powerware 9120 User guide | | | | | | Powerware Three-Phase UPS System | | | | | Eaton Powerware UPS Appliance | Power Range | Topology | | Powerware BladeUPS Powerware BladeUPS System expands power protection from 12 kW to 60 kW in a single industry-standard 19" rack. | 180 to 265 Vac, 311 to 519 Vac | Online, Double-conversion on Demand |  |
| | | | | |
| |