Metered Power Distribution

42U's engineers can help you find the right  Metered Rack PDU solution for your current & future power management needs.

Metered Rack PDU solutions for Server Racks, Computer Rooms, Server Rooms & Data Centers

 
Metered Rack PDU
(Input Plug Type)
AmpsNominal PowerOutputsForm FactorPDU Image
120 Volt Input - 15 Amp (Derated to 12A)
APC
AP7800
(5-15P)
15A 1.4 kW (8) 5-15 1UAPC AP7800 (5-15P) Metered Rack PDUBuy APC AP7800 (5-15P) Metered PDUs Online
APC
AP7831
(5-15P)
15A 1.4kW(16) 5-150UAPC AP7831 (5-15P) Metered Rack PDUBuy APC AP7831 (5-15P) Metered PDUs Online
120 Volt Input - 20 Amp (Derated to 16A)
APC
AP7801
(L5-20P )
20A1.9kW(8) 5-20 1UAPC AP7801 (L5-20P ) Metered Rack PDUBuy APC AP7801 (L5-20P ) Metered PDUs Online
APC
AP7830
(L5-20P)
20A1.9kW(24) 5-200UAPC AP7830 (L5-20P ) Metered Rack PDUBuy APC AP7830 (L5-20P ) Metered PDUs Online
Server Tech
C-10H1-C20
(C20 to 5-15P,5-20P or L5-20P)
20A1.9kW(10) 5-20R1UServer Tech C-10H1-C20 (Select) Metered Rack PDUBuy Server Tech C-10H1-C20 (Select) Metered PDUs Online
Server Tech
C-24V1-C20
(C20 to 5-15P,5-20P or L5-20P)
20A1.9kW(24) 5-20R0UServer Tech C-24V1-C20 (select) Metered Rack PDUBuy Server Tech C-24V1-C20 (select) Metered PDUs Online
120 Volt Input - 30 Amp (Derated to 24A)
APC
AP7802
(L5-30P)
30A2.9kW(16) 5-202UAPC AP7802 (L5-30P ) Metered Rack PDUBuy APC AP7802 (L5-30P ) Metered PDUs Online
APC
AP7832
(L5-30P)
30A2.9kW(24) 5-20 0UAPC AP7832 (L5-30P) Metered Rack PDUBuy APC AP7832 (L5-30P) Metered PDUs Online

(back to top)

Metered Rack PDU
(Input Plug Type)
AmpsNominal PowerOutputsForm FactorPDU Image
208 Volt Input - 20 Amp (Derated to 16A)
Server Tech
C-12H2-C20M
(C20 to L6-20P)
20A3.32kW(12) C131UServer Tech C-12H2-C20M (C20) Metered Rack PDUBuy Server Tech C-12H2-C20M (C20) Metered PDUs Online
Server Tech
C-24V2-C20
(C20 to L6-20P)
20A3.32kW(24) C130UServer Tech C-24V2-C20 (C19 ) Metered Rack PDUBuy Server Tech C-24V2-C20 (C19 ) Metered PDUs Online
208 Volt Input - 30 Amp (Derated to 24A)
APC
AP7811
(L6-30P)
30A5.0kW(12) C13,
(4) C19
2UAPC AP7811 (L6-30P) Metered Rack PDUBuy APC AP7811 (L6-30P) Metered PDUs Online

(back to top)

Metered Rack PDU
(Input Plug Type)
AmpsNominal PowerOutputsForm FactorPDU Image
208V 3-Phase Delta Input - 20 Amp (Derated to 16A)
Server Tech
C-12HDD-L1520
(2 x L15-20P)
20A, 3ø 11.53kW(12) C192UServer Tech C-12HDD-L1520 (L15-20P) Metered Rack PDUCall
800-638-2638

for Best Pricing

Server Tech
C-21VD-L1520
(L15-20P)
20A, 3ø 5.76kW(21) C130UServer Tech C-21VD-L1520 (L15-20P) Metered Rack PDUBuy Server Tech C-21VD-L1520 (L15-20P) Metered PDUs Online
208V 3-Phase Delta Input - 30 Amp (Derated to 24A)
Server Tech
C-12HDD-L1530
(2 x L15-30P)
30A, 3ø 17.29kW(12) C192UServer Tech C-12HDD-L1530 (L15-30P) Metered Rack PDUCall
800-638-2638

for Best Pricing

Server Tech
C-24VD-L30MA
(L15-30P)
30A, 3ø 8.65kW(24) C130UServer Tech C-24VD-L30MA (L15-30P) Metered Rack PDUCall
800-638-2638

for Best Pricing

208V 3-Phase Delta Input - 50 Amp (Derated to 40A)
APC
AP7869
(CS8365C)
50A, 3ø14.4kW(24) C13,
(4) C19,
(2) L6-30
0UAPC AP7869 (CS8365C ) Metered Rack PDUBuy APC AP7869 (CS8365C ) Metered PDUs Online
APC
AP7899
(CS8365C)
50A, 3ø14.4kW(24) C13,
(4) C19,
(2) L6-30
0UAPC AP7899 (CS8365C ) Metered Rack PDUBuy APC AP7899 (CS8365C ) Metered PDUs Online
APC
AP7867A
(CS8365C)
50A, 3ø 14.4kW(6) C19 0UAPC AP7867A (CS8365C ) Metered Rack PDUBuy APC AP7867A (CS8365C ) Metered PDUs Online
APC
AP7868
(CS8365C)
50A, 3ø 12.5kW(30) C13,
(6) C19
0UAPC AP7868 (CS8365C ) Metered Rack PDUBuy APC AP7868 (CS8365C ) Metered PDUs Online
APC
AP7898
(CS8365C)
50A, 3ø 12.5kW(30) C13,
(6) C19
0UAPC AP7898 (CS8365C ) Metered Rack PDUBuy APC AP7898 (CS8365C ) Metered PDUs Online
208V 3-Phase Delta Input - 60 Amp (Derated to 48A)
APC
AP7866
(IEC 309 60A 3P+PE)
60A, 3ø16.2kW(3) C13,
(12) C19
0UAPC AP7866 (3P+PE) Metered Rack PDUBuy APC AP7866 (3P+PE) Metered PDUs Online
APC
AP7866A
(IEC 309 60A 3P+PE)
60A, 3ø16.2kW(3) C13,
(12) C20
0UAPC AP7866A (3P+PE) Metered Rack PDUBuy APC AP7866A (3P+PE) Metered PDUs Online

(back to top)

Metered Rack PDU
(Input Plug Type)
AmpsNominal PowerOutputsForm FactorPDU Image
208V 3-Phase Wye Input - 20 Amp (Derated to 16A)
APC
AP7862
(L21-20P)
20A, 3ø 5.7kW(42) 5-200UAPC AP7862 (L21-20P ) Metered Rack PDUBuy APC AP7862 (L21-20P ) Metered PDUs Online
APC
AP7863
(L21-20P)
20A, 3ø 5.7kW(21) 5-20,
(6) L6-20 
0UAPC AP7863 (L21-20P) Metered Rack PDUBuy APC AP7863 (L21-20P) Metered PDUs Online
APC
AP7892
(L21-20P)
20A, 3ø 5.7kW(42) 5-200UAPC AP7892 (L21-20P ) Metered Rack PDUBuy APC AP7892 (L21-20P ) Metered PDUs Online
APC
AP7893
(L21-20P)
20A, 3ø 5.7kW(21) 5-20,
(6) L6-20 
0UAPC AP7893 (L21-20P) Metered Rack PDUBuy APC AP7893 (L21-20P) Metered PDUs Online
Server Tech
C-12HDY-L2120
(2 x L21-20P)
20A, 3ø 11.4kW(12) C192UServer Tech C-12HDY-L2120 (L21-20P) Metered Rack PDUCall
800-638-2638

for Best Pricing

Server Tech
C-21VY-L2120
(L21-20P)
20A, 3ø 5.7kW(21) C130UServer Tech C-21VY-L2120 (L21-20P) Metered Rack PDUBuy Server Tech C-21VY-L2120 (L21-20P) Metered PDUs Online
208V 3-Phase Wye Input - 30 Amp (Derated to 24A)
Server Tech
C-12HDY-L2130
(2 x L21-30P)
30A, 3ø 17.29kW(12) C192UServer Tech C-12HDY-L2130 (L21-30P) Metered Rack PDUCall
800-638-2638

for Best Pricing

Server Tech
C-24VY-L30M
(L21-30P)
30A, 3ø 8.65kW(24) C130UServer Tech C-24VY-L30M (L21-30P) Metered Rack PDUCall
800-638-2638

for Best Pricing

Server Tech
C-48VDY-L30
(2 x L21-30P)
30A, 3ø 17.29kW(48) C130UServer Tech C-48VDY-L30 (L21-30P) Metered Rack PDUCall
800-638-2638

for Best Pricing

(back to top)

What are Metered Rack PDUs?

Nearly all data center professionals can recall a situation when one too many pieces of equipment were plugged into a rack PDU. The frenzy that ensues after the breaker trips is never fun for anyone. Both a remedy and long term solution, metered PDUs become an asset to any organization that values uptime and reliability.

Metered PDUs provide the data necessary to properly load and balance rack power circuits. The LED display lets administrators know how much headroom exists between current capacity and the maximum draw of the strip. From there, professionals can make informed decisions about equipment installation.

Balancing Redundant Feeds

Data centers with redundant power feeds need to ensure that the load is properly balanced between them. Power metering is especially helpful for this purpose. If each strip is loaded at 40%, one feed can fail, and the other can pick up the load without exceeding the NEC's 80% deration requirement.

Competitive Landscape

Many manufacturers offer metered PDUs. The heavy competition has resulted in great values for data center professionals. The convenience of metering can be had for a reasonable markup over basic PDUs.

The 42U Advantage

42U has mastered rack power distribution. We make objective product recommendations based on a holistic analysis of your current environment and future requirements. Contact a product specialist today at 1-800-638-2638.

Top Rack PDU Solutions

What is the best Metered Rack PDU Solution for your power needs?
 Data Center Consultation
Our engineers can help you select the best metered Rackmount PDU for your server rack.
Click here or Call 1-800-638-2638 for a free Data Center project consultation.

(back to top)