Metered Rack PDU solutions for Server Racks, Computer Rooms, Server Rooms & Data Centers
Metered Rack PDU - 120V input
| Metered Rack PDU (Input Plug Type) | Amps | Nominal Power | Outputs | Form Factor | PDU Image | View Online Pricing Online pricing is provided by |
| 120 Volt Input - 15 Amp (Derated to 12A) | ||||||
| APC AP7800 (5-15P) | 15A | 1.4 kW | (8) 5-15 | 1U | ![]() | |
| APC AP7831 (5-15P) | 15A | 1.4kW | (16) 5-15 | 0U | ![]() | |
| 120 Volt Input - 20 Amp (Derated to 16A) | ||||||
| APC AP7801 (L5-20P ) | 20A | 1.9kW | (8) 5-20 | 1U | ![]() | |
| APC AP7830 (L5-20P) | 20A | 1.9kW | (24) 5-20 | 0U | ![]() | |
| Server Tech C-10H1-C20 (C20 to 5-15P,5-20P or L5-20P) | 20A | 1.9kW | (10) 5-20R | 1U | ![]() | |
| Server Tech C-24V1-C20 (C20 to 5-15P,5-20P or L5-20P) | 20A | 1.9kW | (24) 5-20R | 0U | ![]() | |
| 120 Volt Input - 30 Amp (Derated to 24A) | ||||||
| APC AP7802 (L5-30P) | 30A | 2.9kW | (16) 5-20 | 2U | ![]() | |
| APC AP7832 (L5-30P) | 30A | 2.9kW | (24) 5-20 | 0U | ![]() | |
metered Rack PDU - Single Phase 208v INPUT
| Metered Rack PDU (Input Plug Type) | Amps | Nominal Power | Outputs | Form Factor | PDU Image | View Online Pricing Online pricing is provided by |
| 208 Volt Input - 20 Amp (Derated to 16A) | ||||||
| Server Tech C-12H2-C20M (C20 to L6-20P) | 20A | 3.32kW | (12) C13 | 1U | ![]() | |
| Server Tech C-24V2-C20 (C20 to L6-20P) | 20A | 3.32kW | (24) C13 | 0U | ![]() | |
| 208 Volt Input - 30 Amp (Derated to 24A) | ||||||
| APC AP7811 (L6-30P) | 30A | 5.0kW | (12) C13, (4) C19 | 2U | ![]() | |
Metered Rack PDU - 3-PHase 208V Delta INPUT
| Metered Rack PDU (Input Plug Type) | Amps | Nominal Power | Outputs | Form Factor | PDU Image | View Online Pricing Online pricing is provided by |
| 208V 3-Phase Delta Input - 20 Amp (Derated to 16A) | ||||||
| Server Tech C-12HDD-L1520 (2 x L15-20P) | 20A, 3ø | 11.53kW | (12) C19 | 2U | ![]() | Call 800-638-2638 for Best Pricing |
| Server Tech C-21VD-L1520 (L15-20P) | 20A, 3ø | 5.76kW | (21) C13 | 0U | ![]() | |
| 208V 3-Phase Delta Input - 30 Amp (Derated to 24A) | ||||||
| Server Tech C-12HDD-L1530 (2 x L15-30P) | 30A, 3ø | 17.29kW | (12) C19 | 2U | ![]() | Call 800-638-2638 for Best Pricing |
| Server Tech C-24VD-L30MA (L15-30P) | 30A, 3ø | 8.65kW | (24) C13 | 0U | ![]() | Call 800-638-2638 for Best Pricing |
| 208V 3-Phase Delta Input - 50 Amp (Derated to 40A) | ||||||
| APC AP7869 (CS8365C) | 50A, 3ø | 14.4kW | (24) C13, (4) C19, (2) L6-30 | 0U | ![]() | |
| APC AP7899 (CS8365C) | 50A, 3ø | 14.4kW | (24) C13, (4) C19, (2) L6-30 | 0U | ![]() | |
| APC AP7867A (CS8365C) | 50A, 3ø | 14.4kW | (6) C19 | 0U | ![]() | |
| APC AP7868 (CS8365C) | 50A, 3ø | 12.5kW | (30) C13, (6) C19 | 0U | ![]() | |
| APC AP7898 (CS8365C) | 50A, 3ø | 12.5kW | (30) C13, (6) C19 | 0U | ![]() | |
| 208V 3-Phase Delta Input - 60 Amp (Derated to 48A) | ||||||
| APC AP7866 (IEC 309 60A 3P+PE) | 60A, 3ø | 16.2kW | (3) C13, (12) C19 | 0U | ![]() | |
| APC AP7866A (IEC 309 60A 3P+PE) | 60A, 3ø | 16.2kW | (3) C13, (12) C20 | 0U | ![]() | |
Metered Rack PDU - 3-PHase 208V Wye INPUT
| Metered Rack PDU (Input Plug Type) | Amps | Nominal Power | Outputs | Form Factor | PDU Image | View Online Pricing Online pricing is provided by |
| 208V 3-Phase Wye Input - 20 Amp (Derated to 16A) | ||||||
| APC AP7862 (L21-20P) | 20A, 3ø | 5.7kW | (42) 5-20 | 0U | ![]() | |
| APC AP7863 (L21-20P) | 20A, 3ø | 5.7kW | (21) 5-20, (6) L6-20 | 0U | ![]() | |
| APC AP7892 (L21-20P) | 20A, 3ø | 5.7kW | (42) 5-20 | 0U | ![]() | |
| APC AP7893 (L21-20P) | 20A, 3ø | 5.7kW | (21) 5-20, (6) L6-20 | 0U | ![]() | |
| Server Tech C-12HDY-L2120 (2 x L21-20P) | 20A, 3ø | 11.4kW | (12) C19 | 2U | ![]() | Call 800-638-2638 for Best Pricing |
| Server Tech C-21VY-L2120 (L21-20P) | 20A, 3ø | 5.7kW | (21) C13 | 0U | ![]() | |
| 208V 3-Phase Wye Input - 30 Amp (Derated to 24A) | ||||||
| Server Tech C-12HDY-L2130 (2 x L21-30P) | 30A, 3ø | 17.29kW | (12) C19 | 2U | ![]() | Call 800-638-2638 for Best Pricing |
| Server Tech C-24VY-L30M (L21-30P) | 30A, 3ø | 8.65kW | (24) C13 | 0U | ![]() | Call 800-638-2638 for Best Pricing |
| Server Tech C-48VDY-L30 (2 x L21-30P) | 30A, 3ø | 17.29kW | (48) C13 | 0U | ![]() | Call 800-638-2638 for Best Pricing |
What are Metered Rack PDUs?
Nearly all data center professionals can recall a situation when one too many pieces of equipment were plugged into a rack PDU. The frenzy that ensues after the breaker trips is never fun for anyone. Both a remedy and long term solution, metered PDUs become an asset to any organization that values uptime and reliability.
Metered PDUs provide the data necessary to properly load and balance rack power circuits. The LED display lets administrators know how much headroom exists between current capacity and the maximum draw of the strip. From there, professionals can make informed decisions about equipment installation.
Balancing Redundant Feeds
Data centers with redundant power feeds need to ensure that the load is properly balanced between them. Power metering is especially helpful for this purpose. If each strip is loaded at 40%, one feed can fail, and the other can pick up the load without exceeding the NEC's 80% deration requirement.
Competitive Landscape
Many manufacturers offer metered PDUs. The heavy competition has resulted in great values for data center professionals. The convenience of metering can be had for a reasonable markup over basic PDUs.
The 42U Advantage
42U has mastered rack power distribution. We make objective product recommendations based on a holistic analysis of your current environment and future requirements. Contact a product specialist today at 1-800-638-2638.
Top Rack PDU Solutions
What is the best Metered Rack PDU Solution for your power needs?
![]()
Our engineers can help you select the best metered Rackmount PDU for your server rack.
Click here or Call 1-800-638-2638 for a free Data Center project consultation.