Liebert Nfinity UPS
Liebert Nfinity UPS

The Liebert Nfinity on-line UPS is a scalable system, designed with N+x parallel redundancy to provide a fault-tolerant network of power protection. The modular design of the Liebert Nfinity was devised to provide easy, user-installed upgrades as power demands grow. Configurations can be cost-effectively upgraded without re-investing in a new system or installation.

Liebert Nfinity Flexibility:

  • Allows addition of battery capacity without increasing footprint.
  • Extends backup time up to 72 hours with additional battery cabinets.
  • Upgrades for capacity or redundancy without the expense or installation downtime associated with the purchase of a new UPS.
  • Enables greater system control with remote management software.
Liebert Nfinity Higher Availability:

  • Offers hot-swappable power, battery, control and display modules, allowing installation or replacement without compromising power to the load.
  • Provides redundant components at critical points of UPS operation.
  • Allows maintenance to be performed without shutdown.
  • Offers emergency power-off capability.
  • Transfers seamlessly to and from the bypass source, with patent pending intelligent bypass technology.
  • Operates with a wider input voltage window for fewer transfers to battery, saving battery wear and tear.
  • Provides compatibility with backup generator — handles frequency variations and other power fluctuations that occur during generator operation.
  • Sustains 110% of the system’s rated load for an extended period of time — the highest overload capability of any system in its class.
Liebert Nfinity Lowest Total Cost of Ownership:

  • Ships as a complete, fully tested system, ready for final connection.
  • Reduces maintenance costs with modular batteries, controls and power components.
  • Allows scalability to cost effectively invest in added capacity as it is needed.
  • Ships with batteries connected and charged, reducing installation time and costs.
Liebert Nfinity is Ideally Suited For:

  • Small-to-medium-sized data centers
  • Network closets
  • VoIP

Click here for a Free UPS System Project Evaluation

Liebert Nfinity UPS Technical Specifications

Model Number8 Bay12 Bay
Power Rating
Rating, VA4, 8, 12, 16kVA4, 8, 12, 16, 20kVA
Rating, W2.8, 5.6, 8.4, 11.2kW2.8, 5.6, 8.4, 11.2, 14kW
Input AC Specifications
Phase22
Power Factor>0.98>0.98
Input Frequency, Hz6060
Frequency Rance, Hz40 - 7040 - 70
Input Voltage208/240208/240
Input Voltage Range+10, -20+10, -20
General Specifications
UPS TechnologyOn-LineOn-Line
Battery Specifications
Battery Test TypeOn-LineOn-Line
Battery Technology VRLA VRLA
Output AC Specifications    
Nominal Voltage 120/208 120/208
Output Waveform Sinewave Sinewave
Nominal Current, Amps 50 or 60 50 or 60
Communications    
Communications Options SNMP/RS232 SNMP/RS232
Software and Cable Multilink SW & Serial Cable Multilink SW & Serial Cable
Physical Data    
Unit Height, inches (mm) 40 (1,016) 54 (1,372)
Unit Depth, inches (mm) 28 (711) 28 (711)
Unit Weight, lbs. (kg) 20 (508) 20 (508)
Environmental    
Operating Temperature, Minimum °F (°C) 32 (0) 32 (0)
Operating Temperature, Maximum °F (°C) 104 (40) 104(40)
Storage Temperature, Maximum °F (°C) 158 (70) 158 (70)
Relative Humidity 0% to 95%, Non Condensing 0% to 95%, Non Condensing
Operating Elevation, ft. (m) to 3,300 (1,000) to 3,300 (1,000)
Storage Elevation, ft. (m) to 40,000 (12,200) to 40,000 (12,200)
Sound Emmision/Audible Noise < 62 dBA, at 1 meter < 62 dBA, at 1 meter
Cooling Fan Cooled Fan Cooled
Agency/Certification/
Conformance
    
Agency Approval cUL Listed, FCC Part 15, Subpart B, Class A, UL 1778, UL Listed cUL Listed, FCC Part 15, Subpart B, Class A, UL 1778, UL Listed
Warranty    
Standard 2 years 2 years
Extended Call 1-800-638-2638 to speak with a Data Center Infrastructure Consultant for additional service contract offerings on this product.
 
 Liebert UPS Systems 
 
Liebert UPS AppliancePower RangeTopologyRackmount
Liebert GXT2500 - 3000 VAOnline UPS2U
Liebert GXT26 & 10 kVAOnline UPS4U & 6U
Liebert Nfinity4 - 20 kVAOnline UPSStandalone
 
   
 Liebert Air Conditioning 
 
Liebert Cooling ApplianceDescription
Liebert XDF High Heat Density Enclosure
Liebert MCRMini Computer Room Enclosure
Liebert ChallengerFloor Mount Precision Cooling System
 
   
 Liebert Water Coolant Systems 
 
Liebert Cooling ApplianceDescription
Liebert XDK-WRack Enclosure with Integrated Water-Based Cooling for High Heat Density Electronics
Liebert XDR-WBack-of-Rack Cooling Module
Liebert XDP-WWater-Based Cooling Pumping Unit
 
   
 


Liebert Nfinity--Liebert Nfinity Scalable On-line UPS