Great Lakes Lake Effect Thermal Enclosure

The Great Lakes Lake Effect (LE) Thermal Enclosure utilizes the proprietary concept of accelerated ambient cooling to provide an even flow of low temperature air to the front intake face of the servers inside. This air is used by the computer's internal fans to cool the equipment. The number of servers that can be placed in an enclosed cabinet is  directly related to the amount of air available to cool the equipment. The temperature available at the base on the fan box is limited to the ambient temperature associated with CRAC output or base room temperature.

An Environmentally Responsible Approach

  • The Lake Effect requires no infrastructure changes to implement

  • No water or refrigerants are introduced into the data center

  • There is no additional piping, duct work or floor modifications

  • Does not invade under floor static pressure

  • Moves cool aisle into front of cabinet

  • Can be placed, configured & become operational, immediately

  • Maximizes available ambient air, conditioned or not

The Lake Effect makes the most of its environment. It does not require any water, refrigerants, piping , duct work or floor modifications. The enclosure can be placed on an existing data center floor, ready to be configured with servers and can be operational immediately.

Great Lakes Lake Effect Thermal Enclosure Airflow Diagram
Great Lakes Lake Effect Thermal Enclosure Airflow Diagram

The high-performance vanaxial fans in Great Lakes patented front-mounted fan box will accelerate air at the lowest point in the data center or in the area in which the enclosure is located.  If in a raised floor environment, the air will be taken in at the lowest temperature and the highest pressure point, maximizing the cooling effect within the cabinet and within the data center. In any other environment, cold air will seek its lowest point and the fan box will accelerate that air to maximize its cooling potential.

 

Is the Great Lakes Lake Effect Thermal Enclosure the server rack cooling solution for your data center?
Data Center Consultation
Our engineers can help you select the best server rack cooling solution for your data center.
Click here or Call 1-800-638-2638 for a free server rack cooling project evaluation.

Great Lakes Lake Effect Thermal Enclosure
Great Lakes Lake Effect
Thermal Enclosure

The Great Lakes LE Enclosure offers many benefits:

  • Does not require additional piping, duct work, or floor modifications called for by certain high density cabinet systems
  • Enclosure can be placed on an existing data center floor, configured with servers and operate immediately
  • The Lake Effect features numerous innovations including:
    • Two long life vanaxial fans, each rated at 115Volts/.9 Amps
    • Advancements in cable management
    • Numbered rails for "RMU" identification
    • Integral ground lugs
    • Welded 14 gauge steel enclosures, capable of supporting up to 2,000 pounds of rack equipment
  • Reduces operating costs by eliminating equipment failures and optimizing performance of data room air conditioning systems

 

 

 