Rittal LCP+ High Density Cooling System

LCP+ In-Row High Density Cooling (Up to 30 kW)

Rittal's LCP+ brings data center cooling to the rack level, utilizing chilled water in a closed-loop configuration to prevent heat loss and eliminate hot spots, providing 28 kW of useful cooling output. Using Rittal's Liquid Cooling Packages have been proven to reduce energy consumption in data center cooling by 30-45%, making them the perfect addition to the environmentally conscious data center.

Measuring 80" high by 48" deep, the LCP Plus sidecar design includes six fan modules that work in concert with a heat exchanger to scale cooling capacity to 95,540 BTU (28 kW) with a maximum air volume of 2825 cfm (4800 m3/hr). The LCP Plus (and LCP Standard) can be bayed to a single cabinet or between two enclosures. It is also possible to put a pair of LCPs on either side of especially hot cabinets for applications where extreme heat loads are present. As a closed loop solution, the LCP Plus is thermally neutral to the room at large and may be installed in closets, warehouses or wherever precision cooling is required.

The sidecar design prevents water from penetrating the server rack, making it more assembly and service-friendly. LCPs are easy to handle (max. 2 m) and may be transported in lifts and through doors. The low weight means a minimal area load.

Rittal LCP+ Features:

  • Up to 30 kW useful cooling output
  • Sidecar design: Installed adjacent to high density server cabinet(s)
  • Uniform temperature distribution across the entire height of cabinet
  • Variable speed, hot-swappable fan modules
  • 19" mounting unobstructed
  • Optimized for Free Cooling
  • Dimensions: 300 x 2000 x 1200 (W x H x D) (12" x 80" x 48")
  • Integrated condensate management and leakage protection
  • Touchscreen for stand-alone operation
  • Controller with networking capability, compatible with all common communication standards (SNMP, Bacnet etc)

 

Rittal LCP Plus

Is the Rittal LCP+ the best high density solution for your cooling needs?
Data Center Consultation
Our engineers can help you select the best high density solution for your cooling needs.
Click here or Call 1-800-638-2638 for a free high density project consultation.

Rittal LCP Plus High Density Cooling System
Rittal LCP+
High Density Cooling System

The Rittal LCP+ offers many benefits:

Potential Energy Savings
  • Reduce the need for traditional data center climate control and provide the same heat removal capacity for much lower energy usage by utilizing the "Free Cooling" capacity of existing climate control systems.
Flexibility
  • The capability to cool one or two cabinets from a single LCP or LCP Plus system, depending on potential heat loads.

Expandable

  • Providing a scalable system that can grow as the IT installation grows with modular units that provide simple connections to existing facility infrastructure.

Redundancy

  • Can provide multiple levels of redundancy to meet the most demanding installation criteria from N+1 to 2N and beyond.

 

 

 