Data Center Engineering - 42U

Rittal Cold Aisle Containment

Rittal Cold Aisle Containment

 
 
Free Project Consultation
Free Project Consultation
Data Center Curtains - aisle continment curtains
Aisle Containment Curtains

Data Center Design
Data Center Design

Data Center Energy Efficiency Savings Calculator
Efficiency Savings Calculator

 
   
 

Rittal Cold Aisle Containment

Rittal cold aisle containment is a combination of door and roof components which facilitate consistent separation of the hot and cold air in the data centre.

Instead of flooding the data center with cold air, Rittal's cold aisle containment system traps the cool air exactly where it is needed directly in front of the air intake of the servers. Cold air is directed across the whole height of the enclosure ensuring that there are no hotspots and the hot air is exhausted out of the system. Due to the cold aisle being contained there is no chance of the hot exhaust air mixing with the cold inlet air, therefore there is an increase in system efficiency.

The special energy efficiency of the Rittal cold aisle concept has a simple and plausible explanation:

  • Cold and hot air cannot mix, warm air does not flow into the cold aisle.
  • The system can be operated with a much higher extracted air temperature.
  • Standard air circulation cooling units are operated at an optimum thermal efficiency level.

CRAC system and cold aisle containment

Rittal Cold Aisle Containment Airflow Diagram

By using Rittal cold aisle containment, climate control of the room (in conjunction with a CRAC unit) may be optimized for energy efficiency and cooling output.

Benefits:

  • High energy efficiency
  • Increased cooling output per server enclosure
  • Easily retro-fitted to existing systems
  • Protection of your existing infrastructure

LCP Inline and cold aisle containment


Application Example: Cold Aisle Containment with Rittal LCP Inline

In conjunction with the Rittal LCP Inline, cold aisle containment is a further option for the efficient dissipation of high heat loads from server enclosures.

Benefits:

  • A raised floor is not required for climate control
  • To accommodate higher heat loads per server enclosure
  • Redundancies easily achieved
  • Direct supply of cold air to your server and network components

Rittal Cold Aisle Containment
Rittal Cold Aisle Containment

The Rittal Cold Aisle Containment offers many benefits:

Equipment:
  • Slimline door element with viewing window.
  • Stable roof components in a composite metal with a high level of light permeability.
  • Where required, safety glass may also be used.

System benefits:

  • Increased energy efficiency and performance capability of climate control.
  • Superior output density is facilitated, thanks to guaranteed cold air supply.
  • Easily installed and retrofitted, as it is fully compatible with the TS 8 enclosure system.
  • An inexpensive way to boost the performance of your existing plant, lengthening the investment cycle until a replacement needs to be purchased.

Is the Rittal Cold Aisle Containment the best containment solution for your cooling needs?
Data Center Consultation
Our engineers can also help you select the best solution.
Click here or Call 1-800-638-2638 for a free project evaluation.

 

 
Data Center EngineeringData Center Cooling
Data Center Power Data Center Management
Data Center Solutions

Home | Contact Us | About 42U | Careers | Clients | Vendors | Glossary | Press | Copyright | Privacy Policy | Site Map

Follow us on:
42u on Twitter 42U on YouTube 42U on slideshare

Copyright© 2012 42U. All Rights Reserved


Rittal Cold Aisle Containment